background image

Your power meter and light source units will be used to measure loss in dB of the power transmitted into the cable by the light source 
versus power measured on the receiver end by the power meter.  Loss testing is done at wavelengths for the fiber in use, typically 
850nm for multimode and optionally at 1300nm, while single mode is tested at 1310nm and optionally 1550nm.  The measured loss 
can be compared to the estimated loss for the link or “loss budget.”
This testing kit combined with the included reference cables allows for single-ended loss testing of fiber optic cables.   Double ending 
requires additional reference cables (part number SSF-REFCBL-MM = multimode or SSF-REFCBL-SM = single mode).
For set-up, allowable loss, link budget calculations, etc., the Fiber Optic Association (FOA) is a great resource for testing guidelines.  
FOA power testing instructions are included with your kit and should be reviewed prior to using this equipment.  Information on the 
two noted tests above can be found via the FOA at www.thefoa.org, including fiber optic testing methods and standards.

**AAA (1.5 V) BATTERIES REQUIRED.  BATTERIES NOT INCLUDED.  INSERT 3 PER UNIT TO OPERATE.**

1. Select correct light source for fiber type being 
tested (SM = single mode or MM = multimode; 
labeled above screen on left). Turn on both light 
source (OLS) and power meter (OPM). 
Set both the OPM & OLS units to the desired 
wavelength by pressing the wavelength button 
on each unit.

850nm: Typical multimode testing
1310nm: Typical single mode testing

1A.  Wavelength on the OLS is displayed in the 
upper left corner of the screen. Set to desired 
value (press wavelength key.)  
KHz (lower right) will have a numeric reading or 
dashed lines when the laser is on. Dashed lines 
(---) indicate that the laser is in continuous 
wavelength mode. 

1B. Set OPM to same to same wavelength as 
the OLS unit.  Press the wavelength button 
until desired value appears.
Note: Typically 850nm for multimode testing 
and 1310nm for single mode. 
*Use appropriate cables. Aqua = multimode. 
Yellow = single mode.

2. On the OLS press CW button until 1.0 KHz* 
displays in lower right of the screen (see step 
1A image).
*Typical testing configuration for most cables

3. On the OPM, press the “dBM/W” button until 
dBM is the unit listed to the right of the main 
screen read-out (see step 1B image).

4. Plug REFERENCE cable into OLS. 

Note: Do 

not look into laser while unit is on.

SC testing: plug appropriate multimode or 
single mode cable into OLS.
LC testing: Attach appropriate SC to LC 
adapter, then plug MM or SM reference cable 
into adapter.

Adapter: Beige = multimode
Blue = single mode

Cleerline SSF™ TKITE-1xx Test Kit

SSF-TKITE-100/1MM/1SM Quick Start Guide

cleerlinefiber.com

WARNING: LIGHT SOURCE LASER DOES NOT OPERATE AT VISIBLE WAVELENGTH. LIGHT IS NOT VISIBLE WHEN LASER 

IS ACTIVE. TO AVOID THE RISK OF EYE DAMAGE, DO NOT LOOK AT LASER WHEN LIGHT SOURCE IS OPERATIONAL.

Reviews: