10
P2552HW | 2021-04
Apex Tool Group
1
EN
3
Product description
Controller for use in safety-critical tightening.
The controller is primarily used as a control and monitoring
unit for one or more tools at a workstation. Depending on
the peripheral devices that are procured, the controller can
also be installed outside of the work environment.
Software is already installed on the controller. The tighten-
ing settings must be carried out by a qualified person using
the controller or remote PC software (mProRemote) in
order to start fastening work. For further information
regarding software operation, please reference the Pro-
gramming Manual.
Nutrunner controllers with the suffix STO in the type name
are equipped with the STO safety function, see Chapter 9
STO safety function, Page 16.
4
Technical Specifications
Ambient Conditions
Power Supply
Safety Technology
Normative references
For product-relevant EC Directives, as well as the stan-
dards complied with, see the EC Declaration of Conformity.
Features
Data
Operation Site
Indoors
Ambient Temperature
0...45 °C
1
1 Note the derating. See System Handbook NeoTek™
Storage Temperature
-20...70 °C
Type of Cooling
Convection (self-cooling)
Relative Humidity
10...90 %
No Condensation
Working Height
Up to 3000 m
Above Sea Level
1
Protection Class
DIN EN 60529
IP42
Protection Class
DIN EN61140
(VDE 0140-1)
I
Degree of Contamination
EN 61010
2
Transient Overvoltage
EN 61010
CAT
Maximum Shock
DIN EN 60068-2-27
15 G
Maximum Vibration
DIN EN 60068-2-5
59.6–160 Hz: 2 G
Features
Data
Supply Voltage,
Single Phase
100–240 VAC ± 10%
1
1 When operating outside the allowable voltage limits,
the integrated power supply enters a protection mode
and switches off. This protection mode can be reset
by restarting the nutrunner controller.
Rated Supply Current
2–1 A
Frequency
50/60 Hz
Peak Current
16 A
Rated Power
1600 VA max.
Idling
40 VA
Safety indices
Safety
function
STO
Safe start lockout (STO, Safe
Torque Off) in accordance with
EN 61800-5-2, with SIL 2
Safe start lockout (STO, Safe
Torque Off) in accordance with
EN ISO 13849-1, Category 3 and
PL d
SIL
SIL 2
Safety level (Safety Integrity
Level) in accordance with EN
61800-5-2
Category 3
Classification in the category is in
accordance with EN ISO 13849-1
PL
PL d
Performance Level is in accor-
dance with EN ISO 13849-1
DCavg
60%
Low, average diagnostic cover-
age (Average Diagnostic Cover-
age)
HFT
1
Hardware Failure Tolerance
SFF
> 60%
Safe Failure Fraction
PFH
9.1 E-10 1/h < 0.1% of SIL 2, Probability of
dangerous Failure per Hour
PFDav
(T = 20 a)
7.9 E-05
0.8% of SIL 2, Probability of dan-
gerous Failure on Demand
T
PTI
[months]
12
Proof Test Interval service life in
accordance with EN ISO 13849-1
MTTFd
> 2.000 a
HIGH, Mean time to dangerous
failure