Troubleshooting
9
EN
Problem
Possible cause
MeasuremPro400GCD
(SW S168813)
Measure for mPro400S… (e.g.
SW S168841)
a
WLAN data communication between controller and tool
No WLAN data com-
munication between
the controller and
the tool.
The IP address of
the tool is not cor-
rectly entered in the
controller.
1.
On the controller screen
Tool setup
, check whether
the IP address of the tool
has been entered in the
Type
box.
2.
Otherwise, mark the line
and <Edit>.
IP address of tool – see Tool in
RF settings
submenu.
1.
Press <
> on the control-
ler.
2.
Select the required tool
under
Station #
>
Tool
assignment
.
3.
Press <
>.
4.
Enter the IP address under
Tool address
.
IP address of tool – see Tool in
RF settings
submenu.
Tool not yet parame-
terized with the cor-
rect WLAN settings.
On the controller screen
Navigator > Utilities > Sys-
tem settings > LiveWire/
CellCore RF configuration
,
use the infrared interface to
parameterize the tool with
the correct WLAN settings.
1.
On the controller screen
Main menu > System pro-
gramming > Service > TMA
configuration > Communi-
cation with tool
, select >
RF
mode
WLAN.
2.
Parameterize the tool with
the correct settings via the
infrared interface.
WLAN settings are
different for control-
ler and access
point.
On the controller screen
Navigator > Utilities > Sys-
tem settings > LiveWire/
CellCore RF configuration
,
check whether the tool's
WLAN settings agree with
the settings of the access
point (network name,
encryption, network key).
On the controller screen
Main menu > System pro-
gramming > Service > TMA
configuration > Communi-
cation with tool
, check
whether the WLAN settings
for the tool agree with the
settings for the access point
(network name, encryption,
network key).
A filter for MAC
addresses is acti-
vated at the access
point.
Add the MAC address for the tool to the list of approved
addresses at the access point.
MAC adress of tool – see
•
Label above the battery
•
On the tool in the
RF settings
submenu.
Port 4001 is dis-
abled by a firewall.
Configure the firewall such that the required IP/MAC addresses
can use port 4001.
The wireless chan-
nel at the access
point is outside the
range supported by
the tool.
To change the wireless channel setting at the access point to the
right wireless channel with respect to country code:
EU 1–13; World 1–11 (see Installation Manual P1894E).
Tool is already
assigned to another
controller.
Check whether another controller already has a connection to
this tool. In other words, another controller is using the same IP
address.
IP address cannot
be pinged.
IP address already
exists in network. In
this case, the tool
will not establish a
connection.
Check the physical connection (RSSI values).
Check the assigned IP address.