26
P2070BA/EN 2011-06
70b_1_5 en.fm, 12.03.2015
Troubleshooting
6
6
Troubleshooting
7
Service
Keep contacts free from contaminations. This is the only way to ensure smooth functioning.
8
Maintenance
NOTE
If repair is required, send the complete battery to our Sales & Service Center!
It may be repaired only by authorized technicians. Opening the battery will void the warranty.
9
Technical data
Problem
Possible cause
Measure
Expected number of test
rundowns is not
achieved with one
charge of the battery.
Battery is not fully charged.
Use fully charged battery.
The warning threshold for undervol-
tage is not set to minimum value.
Set the undervoltage to 37,2 Volt
using the control on the
tool
screen.
A high torque was required for the
rundowns, e.g. for coated screws or
for several revolutions.
Using a high torque for a longer
period of time will reduce the number
of rundowns to be achieved with one
battery charge.
Battery has too many charging
cycles.
After 800 charging cycles the capac-
ity is reduced to approx. 60%.
No LCD display
Battery is in Deep Sleep Mode
Recharge battery with charger
Battery is defective
Replace battery
Changing LCD display
Battery temperature is > 118.4°
C
Leave the battery to cool. Display
expires.
Battery detecting short-circuit
Remove short-circuit.
Push battery on to battery
charger. This will reset the error
message.
Charger indicates bat-
tery fault
Battery is defective
Replace battery
Features
Data
Battery type
Lithium ions (Li-Ion), 12 cells
Nominal capacity
1650 mAh / 72.6
Wh
Rated voltage
44.4 V
Maximum voltage
50.4 V
Battery self-discharge
1
:
Default settings
Fully charged
100 days
360
days
Weight
850
g
EN
Summary of Contents for 936400PT
Page 2: ...2 P2070BA INT 2011 06 70a_ Deckblatt_int fm 12 03 2015...
Page 12: ...12 P2070BA CS 2011 06 2070b_1_5 cs fm 12 03 2015 Likvidace 10...
Page 20: ...20 P2070BA DE 2011 06 70b_1_5 de fm 12 03 2015 Entsorgung 10...
Page 28: ...28 P2070BA EN 2011 06 70b_1_5 en fm 12 03 2015 Disposal 10...
Page 36: ...36 P2070BA ES 2011 06 70b_1_5 es fm 12 03 2015 Eliminaci n 10...
Page 44: ...44 P2070BA FR 2011 06 70b_1_5 fr fm 12 03 2015 Elimination 10...
Page 52: ...52 P2070BA IT 2011 06 70b_1_5 it fm 12 03 2015 Smaltimento 10...
Page 60: ...60 P2070E PL 2011 06 70b_1_5 pl fm 12 03 2015 Utylizacja 10...
Page 68: ...68 P2070BA PT 2011 06 2070b_1_5pt fm 12 03 2015 Descarte 10...
Page 69: ...70b_1_5 zh fm 12 03 2015 P2070BA ZH 2011 06 69 1 Apex Tool Group Apex Tool Group 1 1 1...
Page 72: ...72 P2070BA ZH 2011 06 70b_1_5 zh fm 12 03 2015 4 0 C 40 C 32 V 10 75 4 4 1 4 2 800 60 100 2 1...
Page 75: ...70b_1_5 zh fm 12 03 2015 P2070BA ZH 2011 06 75 10 10 ElektroG BattG...
Page 76: ...76 P2070BA ZH 2011 06 70b_1_5 zh fm 12 03 2015 10...