6
SOLENOID RETAINER
PLUNGER PIN
HAT
.015/.020
1. Solenoid plunger pin to hat dimension should be .015/.020 as shown. A new plunger pin should be
spaced as shown; however, a previously used plunger pin must be pressed to this dimension.
2. Assemble the solenoid components as shown. Solenoid retainer must be torqued to 10 to 12 ft. lbs.
using 242 Loctite. Note: Overtightening may damage solenoid body. Undertightening may result in
air leakage that may affect operation.
3. Connect tool to air supply. Air supply operating pressure should be between 40 and 90 PSI.
ADJUSTMENT SCREW
K
K
L
L
(+) SOLENOID
(-) SOLENOID
TOOL RECEPTACLE
CABLE CONNECTORS
BLACK
RED
SOLENOID SPECIFICATIONS
6V DC-8V DC CONTINUOUS VOLTAGE
24V DC-36V DC FOR 15 msec MAX.
14.95ohm RESISTANCE
TRANDUCER
WHITE
BLACK
GREEN
RED
A + EXCITATION
BLACK
GREEN
RED
SHIELD
CAMBION
CONNECTORS
6 PIN CONNECTOR
WHITE
B - EXCITATION
C + SIGNAL
D - SIGNAL
E SHIELD
A + SOLENOID
RED
RED
SOLENOID
CAMBION
CONNECTORS
BLACK
BLACK
FIXTURE MOUNTED SOLENOID CONTROL TOOL WIRING DIAGRAM
B - SOLENOID
C
3 PIN CONNECTOR
F