3.  Remove the top cap. This will give you a clear view into the top of the air purifier. The photo on the right  

shows the UV chamber with the UV lamp inserted in its center. Note that the UV chamber has a half-
round notch in its wall and that the lamp end cap has a groove in its top. The notch and the groove will 
be in alignment.

4.  Wear a pair of leather gloves. While holding down the air purifier on the counter with one hand, grasp 

the lamp end cap with the other hand, and pull the UV lamp straight out. Note that it does not require 
much force to “un-click” the UV lamp from its socket. Do not jerk it out. The UV lamp is fragile; excessive 
force or dropping it may cause it to break. Should the lamp break while it is still in its chamber, do not 
proceed further. Package the entire unit securely and ship it back to ClearWaveAir Corporation (see 
ClearWaveAir.com for the address and shipping instructions). The unit will have to be cleaned of all 
debris and contaminants before it is reassembled and returned to you.

Summary of Contents for CWA200

Page 1: ...Model CWA200 Owner s Manual...

Page 2: ...ted by our warranty 2 For updated safety and operating instructions 3 For information about improving the air quality in your home or office 4 For patent information ClearWaveAir is a registered trade...

Page 3: ...eAir 3 Table of Contents Safety Instructions 4 ImportantWarnings 5 OperatingThe ClearWaveAir Purifier 6 Cleaning and Maintenance 7 Troubleshooting 12 Warranty 12 ClearWaveAir Inc LasVegas NV ClearWave...

Page 4: ...e the air purifier unit in water or other liquid Never reach for the unit if it has fallen into water Unplug it first Care should be taken so that objects do not fall and liquids are not spilled into...

Page 5: ...is harmful to bare skin and eyes and can cause temporary or permanent loss of vision To prevent exposure to ultraviolet light disconnect the power to the unit before servicing any part of the unit UV...

Page 6: ...robial or chemical compounds in your environment The ClearWaveAir Microbial Kill Chamber will render many of these compounds harmless by destroying them If for instance a particular room has a high mo...

Page 7: ...d 1 Unplug the power supply to the air purifier Turn the air purifier upside down and set it down on a solid surface You may want to set it on a paper towel or soft cloth to prevent scratching of the...

Page 8: ...2 Discard the old filter cartridge and insert the new cartridge The o ring will easily snap into place and secure the filter 3 The o ring will bend until it fully snaps into its groove to retain the f...

Page 9: ...how to send your unti back to us ClearWaveAir s replacement UV lamp is shipped together with replacement and disposal instructions and the required Allen wrench 1 Remove the power supply from the ele...

Page 10: ...on the counter with one hand grasp the lamp end cap with the other hand and pull the UV lamp straight out Note that it does not require much force to un click the UV lamp from its socket Do not jerk i...

Page 11: ...n you are sure that the lamp is properly aligned lightly press down on the lamp until you hear a click This means that the lamp is properly installed 6 You are now ready to reassemble the unit Insert...

Page 12: ...purifier All express and implied warranties for this product including implied warranties of merchantability and fitness for a particular purpose are limited in duration to the warranty period and no...