    Before installation of the Clearstream Treatment Tank, first install a pretreatment tank 
(septic  tank)  with  a  volume  of  not  less  than  50%  of  the  gallon  per  day  rating  of  the 
Clearstream  Unit.    Pretreatment  tanks  shall  comply  with  minimum  sizing  specifications 
outlined in the Clearstream specifications section.

UNLOADING/PACKING INSTRUCTIONS:

1.

All compressors are packaged to prevent damage during shipping and handling.

2.

Please  be  careful  during  shipping  or  handling  of  the  linear  compressors

 

they  are

fragile  and  can  be  damaged  if  dropped  from  only  a  short  distance.    If  dropped

 

hard 

enough  the  cast  aluminum  housing  may  be  damaged  and  render  the  compressor

 

usele

ss.

3.

The most common issue resulting from a linear compressor being handled inappropriately is the

safety  switch  being  tripped.    Please  refer  to  the  repair  manual  for  switch  reset  instructions  if  the

compressor fails to power up.

4.

All control panels are packaged to prevent damage during shipping and handling.

5.

Clearstream

 electrical control 

panels are fragile and should be handled as such during

shipping

 

and  handling.    All 

electrical  control 

panels  have  circuit  breakers,  lights  and

electrical connections

 

and many have relays and timers that are all fragile.  Components

may be replaced

 

if damaged but if the panel enclosure its self is damaged the panel may

be rendered

 

useless.

5

 of 1

2

Summary of Contents for 600DAC3

Page 1: ... 1500 Fax 409 755 6500 www clearstreamsystems com OWNER S MANUAL PARTS LIST OPERATING MANUAL FLOW DIAGRAM INSTALLATION INSTRUCTIONS DESIGN DRAWINGS AND SPECIFICATIONS SERVICE POLICY LIMITED WARRANTY MODEL 600DAC3 NSF ANSI 40 Class I 245 350 1 of 12 ...

Page 2: ...the mixed liquor The mixed liquor passes into the bottom of the clarifier by hydraulic displacement as wastewater enters the aeration chamber Solids settled from the wastewater are drawn back into the aeration chamber from the bottom of the cone by the hydraulic roll created by the air released in the aeration chamber and are dispersed by the mixing induced by the aerator An airlift assembly contr...

Page 3: ...ly To determine if all system components are functioning properly look and or listen to see if the visual audio alarm system is illuminated or making a buzzing sound If the alarm is activated then either the aerator has lost air pressure or the high level float inside the clarifier is indicating a high water level condition Verification of either condition can be made by checking air pressure from...

Page 4: ...l be honored For the Clearstream Aerobic Wastewater Treatment Unit to function properly it must be used for the treatment of domestic wastewater from residences or other waste flows with similar loading characteristics Typical domestic wastewater consists of the flow from toilets lavatories sinks bathtubs showers and washing machines To prevent malfunctions of your Clearstream Unit the following g...

Page 5: ...t distance If dropped hard enough the cast aluminum housing may be damaged and render the compressor useless 3 The most common issue resulting from a linear compressor being handled inappropriately is the safety switch being tripped Please refer to the repair manual for switch reset instructions if the compressor fails to power up 4 All control panels are packaged to prevent damage during shipping...

Page 6: ...re the inlet 4 PVC pipe is aligned properly to incoming sewage line 5 For the Clearstream Unit to function properly the tank must be level To properly level the tank lay a three 3 foot level across the tank in several directions Shift the tank in the hole as necessary to make the tank level in all directions The tank may be slightly out of level but it should not be out of level enough to cause ta...

Page 7: ...ompliance with NFPA 70 for all electrical components electrical connections and system installation 3 Install Clearstream Aerator Model CS 103ET6 as close as practical to the tank but in no case greater than one hundred 100 feet away Run 3 4 Sch 40 PVC air line from aerator connector to the air line connection at Clearstream tank Be careful to backfill under ground air line in manner which will no...

Page 8: ...Intakelevel 600 G P D 1 5 lbs BOD 2 8 scfm Raintight 115v 60Hz 0 75 amps Plant Design Flow 100 of ATU Design Flow 30 Inches 6 inches below liquid 25 to 50 of liquid Inlet flow line must be a minimum of two inches higher than the outlet flow line 1of 12 8 of 12 Model 600DAC3 Treatment Capacity BOD Loading Aerator CS 103ET6 Control Panel Model CS 114 Electrical ...

Page 9: ...E45 TURNS ACCESSCOVERFOR20 OPENING 154 INLET AIRLINE 3 4 PVC 20 ACCESSCOVER AIRSUPPLYDROP3 4 PVC 6 HIGHLEVELALARMFLOAT AIRLIFTASSEMBLY AERATOR AIRLIFTAIRSUPPLY 1 TREATEDEFFLUENTDISCHARGE GRADE AERATOR AIRLIFTSUPPLYLINE 10 AIRLIFTINLET 3 4 FLEXPIPE 3 4 FLEXPIPE CSUV1 optional for Std 40 and 245 applications Required for Std 350 applications 20 ACCESSCOVER CSUV1DISINFECTION PUMPHEADDISCHARGEASSEMBLY...

Page 10: ...4 AERATOR POLYETHYLENE HOUSING 15 AIRLIFT RECYCLE ASSEMBLY 16 GAS BAFFLE 17 FLOW CONTROL WEIR 18 UV DISINFECTION DEVICE optional Std 40 245 req Std 350 PART NUMBER CS 101 CS 102 CS 103ET6 CS 107 CS 108 CS 109 CS 11 CS 113 CS 114 CS 116A CS 116 CS 130 CS 131 CS 106 CS 132 CS 117 CS 111 CSUV1 COMPONENT PARTS MAY BE OBTAINED FROM YOUR LOCAL SERVICING DEALER OR PO BOX 705 BEAUMONT TX 77726 800 586 365...

Page 11: ...erves the right to revise change or modify the construction and design of the Clearstream Aerobic Treatment System or any component part or parts thereof without incurring any obligation to make such changes or modifications in equipment previously sold Clearstream also reserves the right in making replacements of component parts under this warranty to furnish a component which in its judgement is...

Page 12: ...CLEARSTREAM WASTEWATER SYSTEMS INC P O Box 7568 Beaumont Texas 77726 7568 Phone 409 755 1500 Fax 409 755 6500 www clearstreamsystems com Copyright 7 01 2013 Revised 9 8 2021 12 of 12 ...

Reviews: