background image

LIMITED WARRANTY

 

Clearstream Wastewater Systems, Inc. warrants each Clearstream Aerobic Wastewater Treatment System to be free from defects 

in material and workmanship for a period of two (2) years from the date of sale to the original retail consumer when properly registered 
with Clearstream.  Clearstream’s sole obligation under this warranty is as follows:  Clearstream shall fulfill this warranty by repairing or 
exchanging  any component  part,  F.O.B. Factory, that shows  evidence of  defects, provided  said  component  part  has been  paid  for, 
warrantee has  notified  Clearstream of  the  defect  complained  of  and  the  component  is  returned  through  an  authorized  Purchaser, 
transportation prepaid.  There is no informal dispute settlement available under this LIMITED WARRANTY. 

No warranty is made as to the field performance of any system.  This LIMITED  WARRANTY applies only to the parts manufactured by 
Clearstream and does not include any portion  of the plumbing,  drainage, disposal system or installation of the systems.  Site specific 
designs of treatment and disposal systems, including treatment plant and disposal system sizing is not the responsibility of Clearstream 
and is not covered by this LIMITED  WARRANTY.  Accessories supplied by Clearstream, but manufactured by others, are warranted only 
to the extent of and by the terms and conditions  of the original manufacturer’s warranty.  In no event shall Clearstream be responsible 
for  delay  or  damages  of  any  kind  or  character resulting  from,  or  caused  directly  or  indirectly  by,  defective component  or  materials 
manufactured by others. 

Recommendations  for  special  applications  will  be  based  on  the  best  available  expertise  of  Clearstream  and  published industry 
information.  Such recommendations do not constitute a warranty of satisfactory performance. 

The LIMITED  WARRANTY extends to the original  retail consumer of the product.   As herein, original  retail consumer is defined as the 
purchaser who first has the plant installed, or in the case of a system designed for non-permanent installation, the purchaser who first 
uses the system.  It is the purchaser’s, or any sub-vendee’s, obligation  to make known to any other consumer the terms and conditions 
of this warranty. 

This warranty is a LIMITED  WARRANTY and no claim of any nature shall be made against Clearstream unless and until the original retail 
consumer,  or  his  legal  representative, notifies  Clearstream in  writing  of  the  defect  complained  of  and  delivers  the  product  and/or 
defective part(s), freight prepaid, to Clearstream or an authorized service station. 

Clearstream reserves the right to revise, change, or modify the construction and design of the Clearstream Aerobic Treatment System, 
or any component part or parts thereof, without incurring any obligation to make such changes or modifications in equipment previously 
sold.   Clearstream also  reserves the right,  in  making  replacements  of  component  parts  under  this  warranty, to  furnish a component 
which, in its judgement is equivalent to the part replaced. 

To the extent that the LIMITED  WARRANTY statements herein are inconsistent with the locality where Purchaser used the Clearstream 
system, the warranties shall be  deemed  to  be modified  consistent with such  local  law.   Under such  local  law, certain limitations may 
not  apply.   For  example,  some  states  in  the  United  States and  some  jurisdictions  outside  the  United  States may:  (i)  preclude  the 
disclaimers and limitations of these warranties from limiting the rights of a consumer; (ii) otherwise restrict the ability of a manufacturer 
to make such disclaimers or to impose such limitations; or (iii) grant the consumer additional legal rights, specify the duration of implied 
warranties which the manufacturer cannot disclaim, or prohibit  limitations on how long an implied warranty lasts. 

In no  event and  under  no legal theory, including  without limitation, tort, contract, or strict product  liability, shall Clearstream or any of 
its suppliers be  liable to  the other party for any indirect, special, incidental, or  consequential damages of any kind,  including  without 
limitation, damages for loss of goodwill,  or any other kind  of commercial  damage, even if the other party has advised Clearstream of 
the possibility of such damages. 

TWO YEAR INITIAL SERVICE POLICY

 

Date 

Our firm, 

the first two years from the date of installation. There will be 

, will inspect and service your Clearstream System for 

inspections made each year for this initial two year 

period. Effluent quality inspection  will include a visual inspection  for color, turbidity, sludge build  up,  scum overflow, and 
odor. Mechanical and electrical inspection and service include: inspecting aerator, air filter, and alarm panel and replacing 
or repairing any component  not found to be functioning correctly. 

Upon expiration of this policy,  our firm will offer a continuing service policy on a  yearly basis to cover labor for 

normal maintenance and repairs on a year by year basis. 

Violations of warranty include: shutting off the electric current to the system for more than 24 hours, disconnecting 

the  alarm system, restricting  ventilation to  the  aerator, overloading  the  system above  its  rated  capacity,  or  introducing 
excessive amounts of harmful matter into the system, or any other form of unusual abuse. 

THIS POLICY DOES NOT INCLUDE PUMPING 

SLUDGE FROM UNIT IF NECESSARY. 

Service Dealer:  

  Owner

1

1

 of 12

Summary of Contents for 600DAC3

Page 1: ... 1500 Fax 409 755 6500 www clearstreamsystems com OWNER S MANUAL PARTS LIST OPERATING MANUAL FLOW DIAGRAM INSTALLATION INSTRUCTIONS DESIGN DRAWINGS AND SPECIFICATIONS SERVICE POLICY LIMITED WARRANTY MODEL 600DAC3 NSF ANSI 40 Class I 245 350 1 of 12 ...

Page 2: ...the mixed liquor The mixed liquor passes into the bottom of the clarifier by hydraulic displacement as wastewater enters the aeration chamber Solids settled from the wastewater are drawn back into the aeration chamber from the bottom of the cone by the hydraulic roll created by the air released in the aeration chamber and are dispersed by the mixing induced by the aerator An airlift assembly contr...

Page 3: ...ly To determine if all system components are functioning properly look and or listen to see if the visual audio alarm system is illuminated or making a buzzing sound If the alarm is activated then either the aerator has lost air pressure or the high level float inside the clarifier is indicating a high water level condition Verification of either condition can be made by checking air pressure from...

Page 4: ...l be honored For the Clearstream Aerobic Wastewater Treatment Unit to function properly it must be used for the treatment of domestic wastewater from residences or other waste flows with similar loading characteristics Typical domestic wastewater consists of the flow from toilets lavatories sinks bathtubs showers and washing machines To prevent malfunctions of your Clearstream Unit the following g...

Page 5: ...t distance If dropped hard enough the cast aluminum housing may be damaged and render the compressor useless 3 The most common issue resulting from a linear compressor being handled inappropriately is the safety switch being tripped Please refer to the repair manual for switch reset instructions if the compressor fails to power up 4 All control panels are packaged to prevent damage during shipping...

Page 6: ...re the inlet 4 PVC pipe is aligned properly to incoming sewage line 5 For the Clearstream Unit to function properly the tank must be level To properly level the tank lay a three 3 foot level across the tank in several directions Shift the tank in the hole as necessary to make the tank level in all directions The tank may be slightly out of level but it should not be out of level enough to cause ta...

Page 7: ...ompliance with NFPA 70 for all electrical components electrical connections and system installation 3 Install Clearstream Aerator Model CS 103ET6 as close as practical to the tank but in no case greater than one hundred 100 feet away Run 3 4 Sch 40 PVC air line from aerator connector to the air line connection at Clearstream tank Be careful to backfill under ground air line in manner which will no...

Page 8: ...Intakelevel 600 G P D 1 5 lbs BOD 2 8 scfm Raintight 115v 60Hz 0 75 amps Plant Design Flow 100 of ATU Design Flow 30 Inches 6 inches below liquid 25 to 50 of liquid Inlet flow line must be a minimum of two inches higher than the outlet flow line 1of 12 8 of 12 Model 600DAC3 Treatment Capacity BOD Loading Aerator CS 103ET6 Control Panel Model CS 114 Electrical ...

Page 9: ...E45 TURNS ACCESSCOVERFOR20 OPENING 154 INLET AIRLINE 3 4 PVC 20 ACCESSCOVER AIRSUPPLYDROP3 4 PVC 6 HIGHLEVELALARMFLOAT AIRLIFTASSEMBLY AERATOR AIRLIFTAIRSUPPLY 1 TREATEDEFFLUENTDISCHARGE GRADE AERATOR AIRLIFTSUPPLYLINE 10 AIRLIFTINLET 3 4 FLEXPIPE 3 4 FLEXPIPE CSUV1 optional for Std 40 and 245 applications Required for Std 350 applications 20 ACCESSCOVER CSUV1DISINFECTION PUMPHEADDISCHARGEASSEMBLY...

Page 10: ...4 AERATOR POLYETHYLENE HOUSING 15 AIRLIFT RECYCLE ASSEMBLY 16 GAS BAFFLE 17 FLOW CONTROL WEIR 18 UV DISINFECTION DEVICE optional Std 40 245 req Std 350 PART NUMBER CS 101 CS 102 CS 103ET6 CS 107 CS 108 CS 109 CS 11 CS 113 CS 114 CS 116A CS 116 CS 130 CS 131 CS 106 CS 132 CS 117 CS 111 CSUV1 COMPONENT PARTS MAY BE OBTAINED FROM YOUR LOCAL SERVICING DEALER OR PO BOX 705 BEAUMONT TX 77726 800 586 365...

Page 11: ...erves the right to revise change or modify the construction and design of the Clearstream Aerobic Treatment System or any component part or parts thereof without incurring any obligation to make such changes or modifications in equipment previously sold Clearstream also reserves the right in making replacements of component parts under this warranty to furnish a component which in its judgement is...

Page 12: ...CLEARSTREAM WASTEWATER SYSTEMS INC P O Box 7568 Beaumont Texas 77726 7568 Phone 409 755 1500 Fax 409 755 6500 www clearstreamsystems com Copyright 7 01 2013 Revised 9 8 2021 12 of 12 ...

Reviews: