27
CLEARSPAN
™
GREENHOUSES
Revision date: 07.22.11
After adjustments are made, slide one door to its open
13.
position and install two Tek screws through the door
track to prevent the door from sliding out of the track.
Arrows show the locations of Tek screws (two at each
end) used as door stops. Tek screws are installed
through the front of the door track.
Repeat the previous step for the remaining door.
14.
Install the door handle in the desired location. Door
15.
handle is attached using Tek screws.
Continue by reading the
16.
CARE AND MAINTENANCE
information that follows.
Use the FA4482B
Tek screws to secure
handle through the
polycarbonate panel
and
into the door
frame
.
ASSEMBLE AND ATTACH SLIDING DOORS (continued)
SHELTER CARE AND MAINTENANCE
Proper care and maintenance of the shelter is important.
Check the following items periodically to properly maintain
the shelter:
Regularly check the polycarbonate panels to see
•
that these are secure and in good condition. Replace
damaged panels if needed.
Check connections and all fasteners to verify that they
•
remain tight.
Do not climb or stand on the greenhouse at anytime.
•
(See the ridge cap installation notes.)
Inspect the anchoring system to verify that all
•
components remain tight and in good condition.
Remove debris and objects that can accumulate on the
•
greenhouse. Use tools that will not damage the cover
when removing debris.
Remove snow to prevent excess accumulation. Use
•
tools that will not damage the polycarbonate panels
when removing snow.
Check the contents of the shelter to verify that nothing
•
is touching the polycarbonate panels that could cause
damage.
If the greenhouse is moved, inspect all parts and
•
connections before it is reassembled.
Depending on the contents, construction of the shelter,
•
shelter materials, and shelter location, the potential for
condensation exists. ClearSpan™ offers several items
that can be used to alleviate a condensation condition.
Please contact a ClearSpan™ representative for
additional information.
For replacement or missing parts, call 1-800-245-9881
•
for assistance.
NOTE:
With the exception of Truss Arch buildings,
ClearSpan™ shelters and greenhouses
do not
have any
tested loading criteria.