BEAMFORMING MICROPHONE ARRAY 2

2

THE BEAMFORMING MICROPHONE ARRAY 2

The Beamforming Microphone Array 2 (BFM2) is a 2nd generation 
Beamforming Microphone Array product featuring 24 microphones, and 
beamforming and adaptive steering technology designed specifically for 
the CONVERGE® Pro 2 (CP2) products: 128, 128D, 128T, 128TD, 128V, 
128VD, 120, 48T, and 48V. The BFM2 connects with the CONVERGE Pro 
2 through a Peripheral Link (P-Link) port with either Regular (200 ft.) or 
Long Distance (650 ft.) P-Link cables. Three arrays are supported per 
CP2 via either Regular or Long Distance P-Link, and up to 6 BFM2s can 
be daisy-chained in one Regular P-Link chain with a stack of two CP2 
mixers. Power to the BFM2 is supplied through a Power-Over-Ethernet 
(PoE) or P-Link connection from CP2.
The BFM2 is supported by ceiling-mounted, wall-mounted or tabletop 
assembly.

IMPORTANT: 

The BFM2 only can be used with CP2 systems. 

It is not compatible with CONVERGE Pro or first generation 
Beamforming Microphone Array systems.

The latest version of the CP2 firmware can be found on the ClearOne 
website at:

http://www.clearone.com/resources#professional_audio

The latest version of the BFM2 firmware and the Beamforming 
Microphone Array 2 Installation Guide can be found on the ClearOne 
website at:

http://www.clearone.com/resources#professional_microphones

Summary of Contents for Beamforming Microphone Array 2

Page 1: ...Beamforming Microphone Array 2 Group Microphone for Professional Conferencing Quick Start Guide...

Page 2: ...NG MICROPHONE ARRAY 2 2 QUICK START OVERVIEW 3 CONNECTING THE BFM2 4 UPDATE BFM2 FIRMWARE 6 TEST THE BFM2 6 Volume Mute 6 Microphone Array LED Indicators 7 MOUNT THE BFM2 7 COMPLIANCE 8 Part Numbers 8...

Page 3: ...ot fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the po...

Page 4: ...tance P Link and up to 6 BFM2s can be daisy chained in one Regular P Link chain with a stack of two CP2 mixers Power to the BFM2 is supplied through a Power Over Ethernet PoE or P Link connection from...

Page 5: ...6 BFM2s per Regular P Link chain with 2 CP2 unit stack More CONVERGE Pro units may be added to increase the number of BFM2s per site Quick Start Procedures These steps must be done in the following or...

Page 6: ...will not work for this A PoE injector can either be connected to P Link PoE port on the rack mounted CP2 unit or it can be connected directly to the BFM2 s PoE In port When the PoE injector is connec...

Page 7: ...ber 910 001 004 will power a single P Link device Some third party PoE injectors will work but not all Mode B PoE injectors that meet the PoE IEEE 802 3at specification should power three devices PoE...

Page 8: ...le Scenario 2 Connecting four BFM2 units in the same chain with a two CP2 unit stack via the 200 ft cable set The 650 ft cable set cannot be used in a daisy chain of more than 3 BFM2 units per CP2 uni...

Page 9: ...units connected via the P Link on the site are simultaneously updated 8 Restore the saved site file to the system using CONVERGE Pro 2 CONSOLE TEST THE BFM2 The BFM2 must be added to the site using t...

Page 10: ...array can be ceiling mounted in either a suspended or solid ceiling or on a wall mount assembly with the PoE or P Link wiring passing through the mounting assembly and plugging into the BFM2 unit Tabl...

Page 11: ...kit without Suspension Column 910 3200 203 910 3200 203 B BFM Ceiling Mount kit with 12 suspension column 910 001 005 12 910 001 005 12 B BFM Ceiling Mount kit with 24 suspension column 910 001 005 2...

Page 12: ...11 International Tel 1 801 975 7200 e mail global clearone com Sales Tel 801 975 7200 e mail sales clearone com TechSupport Tel 801 974 3760 e mail tech support clearone com CLEARONE LOCATIONS Support...

Reviews: