ClearFox CU-M Quick Start Manual Download Page 6

ClearFox®Control Unit CU-M

-

Overfill Float Switch: Optional. 

Connected to the digital input terminal 

DI1

 inside the

controller (see chapter 5).

6.2

 

P

UMP

-SBR 

Output functions can be selected via web pages. 

-

Blower (+Valve) / Injection Aerator

: Connected to the electric socket of the 

ClearFox®Control Unit CU-M

 (+Out 5) / electric socket

.

-

Pumps / Valves

:

o

Filling: Direct submersible pump - Out 2; using the Sludge Pump 

 Sludge Pump 

Out 4

o

Clearwater removal: Pump Out 3 / Valve Out 3 (+Blower)

o

Sludge return: Pump Out 4 / Valve Out 4 (+Blower)

-

BonFlash

 alarm beacon

 is connected to the terminals marked with 

BF-C

 (brown cable)

 

and 

GND

 (white cable), (see chapter 5).

-

Overfill Float Switch: Optional. 

Connected to the digital input terminal 

DI1

 inside the

 

Sequetrol

® IoT

 (see chapter 5).

6.3

 

O

NE

-T

ANK 

SBR 

Output functions can be selected via web pages. 

-

Blower (+Valve) / Injection Aerator

: Connected to the electric socket of the

ClearFox®Control Unit CU-M

 

 (+Out 5) / electric socket

.

-

Sludge return

: Pump Out 3 / Valve Out 3 (+Blower)

-

BonFlash

 alarm beacon

 is connected to the terminals marked with 

BF-C

 (brown cable)

and 

GND

 (white cable), (see chapter 5).

-

Overfill Float Switch: Optional. 

Connected to the digital input terminal 

DI1

 inside the

ClearFox®Control Unit CU-M

 (see chapter 5).

6.4

 

C

ONTINUOUS PLANTS 

(MBBR,

 

F

IXED

-B

ED

,

 

…)

 

Output functions can be selected via web pages. 

-

Blower (+Valve)

: Connected to the electric socket of the 

ClearFox®Control Unit CU-M

(+Out 5)

-

Pumps / Valves

:

o

Filling: Submersible pump - Out 2 / Airlift 

 Out 2 (+Blower)

o

Clearwater removal: Pump Out 3 / Valve Out 3 (+Blower)

o

Sludge return: Pump Out 4 / Valve Out 4 (+Blower)

-

BonFlash

 alarm beacon

 is connected to the terminals marked with 

BF-C

 (brown cable)

and 

GND

 (white cable), (see chapter 5).

-

Overfill Float Switch: Optional. 

Connected to the digital input terminal 

DI1

 inside the

ClearFox®Control Unit CU-M

 (see chapter 5).

6.5

 

D

RIPPLING FILTER 

(D:

 

T

ROPFKÖRPER

Work in progress…

 

Summary of Contents for CU-M

Page 1: ...1 Quick Start Guide ClearFox Control Unit CU M...

Page 2: ...ed Bed 6 6 5 Drippling filter D Tropfk rper 6 7 Connecting to Wi Fi 7 7 1 Connecting the control unit to the internet via Wi Fi ST mode 7 8 Alarm handling 8 9 Process overviews 8 9 1 Air SBR 8 9 1 1 P...

Page 3: ...ClearFox Control Unit CU M 3 12 2 Transfer via USB 16...

Page 4: ...where you d type www google com http 192 168 117 1 o Username for service login service o Password 1111 same as service menu PIN 3 INTRODUCTION The ClearFox Control Unit CU M platform is a powerful fr...

Page 5: ...t the underside of the printed circuit board and close to the mains supply connectors and the fuse mains voltage 230 V Before removing the casing cover it is necessary to pull the mains supply connect...

Page 6: ...jection Aerator Connected to the electric socket of the ClearFox Control Unit CU M Out 5 electric socket Sludge return Pump Out 3 Valve Out 3 Blower BonFlash alarm beacon is connected to the terminals...

Page 7: ...not forget to push Apply Wi Fi Settings control unit restarts The ClearFox Control Unit CU M can run Wi Fi in Access Point AP and in Station Mode ST AP Wi Fi hotspot without internet connection intra...

Page 8: ...deactivates the Buzzer and the BonFlash output The red LED remains on and the last alarm remains in the Status Screen until the reason for the alarm is gone e g float switch is down again or until th...

Page 9: ...Eco mode o Aeration o Level measurement via Filling If above switching level 1 normal o Each 6 eco cycles frequency can be changed At least one normal mode 9 1 2 Water level measurement Water level m...

Page 10: ...re as it cannot suck anymore water 3 Sludge return for some 60s to increase the level in the pretreatment so that the filling airlift can pump properly again 4 Filling for 20s the pressure at this min...

Page 11: ...over DI1 open Eco Via Sludge Pump ON 10s OFF 14 50min or until DI1 closed On timeout step time over DI1 open Eco o Denitrification 0 40min ON 9 20min OFF 60min Total o Aeration 8min ON 12min OFF 9 5h...

Page 12: ...ssure limits 7 350mbar for Blower applied Pump Out 3 Current limits 300 1800mA for pump applied 9 3 ONE TANK SBR 9 3 1 Process steps For the level measurement overfill alarm a manual calibration must...

Page 13: ...ease ask PPU in case you want to activate it Time taken from the settling time example Settling 2h sludge 2min settling will be 1 58h in reality and sludge 2min sludge return after settling can be dea...

Page 14: ...ower applied Via sludge pump Out 3 Current limits for pump 300 1800mA applied CLEARWATER Blower valve Out 1 2 Current limits for Blower 250 900mA valve 50 150mA applied Generic pressure limits 7 350mb...

Page 15: ...mA valve 50 150mA applied Generic pressure limits 7 350mbar for Blower applied Via sludge pump Out 4 Current limits for pump 300 1800mA applied CLEARWATER ON DAY OFF DAY ON NIGHT OFF NIGHT ON HOLIDAY...

Page 16: ...here click on Start update process done 12 2 TRANSFER VIA USB Please mind that the batteries must be connected Please record the pkg Pack file into the root folder of a common USB stick formatted wit...