Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
20
FieldShield FLATdrop
Installation Manual
_________________________________________________________
Manual 018957 REV C - July 2022
Cleaning Using a Probe-Style Cleaning Tool
• The probe style cleaning tools are capable of cleaning a connector end face separately or through the adapter.
•
Slightly engage probe by pulling back but do not allow to click. Lightly “spot” a QbE-2 wipe on the platen with Elec
-
tro-Wash PX Fiber Optic Cleaner, this will help alleviate “over saturation” of the material.
• Lightly touch the tip of probe and release.
Wipe
Material
Wet
End
Face
Dry
•
Insert connector or insert probe though adapter and click 2-3 times to move past the wet area and allow material to dry
wipe.
•
Inspect connector, repeat if necessary (following standards)
•
If cleaning a male connector, clean the pins (see above)