Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
10
FieldShield D-ROP
Installation Manual
_________________________________________________________
Manual 018958 REV C - Oct 2017
Figure 9
Figure 8
Step 8
:
Insert tool blade into duct
(Figure 8)
.
Step 10
:
Ensure fiber is outside of mechanism
(Figure 10)
.
Step 9
:
Squeeze handle to engage traction
gear.
(Figure 9)
Figure 10
Figure 12
Figure 11
Step 11
:
Turn handle to split duct and allow
fiber to fall out.
(Cut support member if
it interferes with opener’s path.)
(Figure 11)
.
Step 12
:
To finalize the last 1/4 inch of the split,
pull duct across blade by hand
(Figure 12).
Figure 7
Step 7
:
Remove fiber retainer rubber stop from
the end of the duct
(Figure 7)
.