ACCU+ Pow er Supply
User manual / Bedienungsanleitung
5
Clearaudio electronic GmbH 2013
2. Set-up
Before you can use the “
ACCU+ Power Supply”
, you have to insert the provided rechargable
accumulators into the
“ACCU +”
- device.
To avoid a self-discharging the accumulators are not pre-installed before first set-up.
1. Remove the screw on the bottom side of the case with the provided hex-wrench.
Now pull the slide-in module carefully out of the case.
Please take special care of the connection cable during this step.
Now insert the provided accumulators in the intended mounting plates as shown below.
Please pay attention to the correct fit of the contacts, before you engage with light pressure
into the mount. Now push the slide in module carefully back into the housing and lock it with
the screw on the button side.
Please note:
When the “
ACCU+ Pow er Supply”
leaves our factory, the supplied, rechargeable
accumulators (NiMH-type) are fully charged.
Please keep in mind, that the capacity of the accumulators decreases, when the unit
is not in use for a few weeks.
To avoid self-discharging of the accumulators they are not inserted in the
“ACCU+ Pow er Supply”.
If your
“ACCU+ Pow er Supply”
is not in use for longer than one (1) week, please
remove the rechargeable accumulators to avoid a total discharge.
2. Make sure that the central switch is in position “charge mode”.
3. Please connect the “
ACCU+ Power Supply”
to your Clearaudio
”+ Series”
phonostage with
the shielded 15-pole cable.
4. Now connect the power supply unit of your phonostage with the mains supply.
5. Now the accumulators are charging.
6. Before first use, please wait until both “charge full” LED-lights are glowing constantly.
Then the accumulators are fully loaded and the “ accu ready“ LED lights up.
7.If you want to switch your phonostage into the “accu mode” please press the
button „accu mode“.