P 12
E.) Balancing the Pool’s Water
(Continued)
ООО "Бассейн-Сервис" – продажа и монтаж оборудования для бассейнов.
Тел: 8 (800) 700-65-50,
Before installing the
MineralPURE
unit, the copper level should be tested. There may be readings of copper sulfate in the
water from leached copper piping or from a copper based algaecide. Correct the problem by either locating the copper pipe
(usually next to a water heater) and balancing the pH, or eliminating any algaecides completely. Shock the pool with an
extra heavy dose of chlorine to get rid of the algaecides.
If using the Copper/Silver electrode CLE-42 or CLE-44, the table below will allow you to lookup the calculated silver
content in your water based upon measured copper levels.
Reading using the CLA-41 Copper
Test Kit in PPM
Calculated Silver Level if using
the CLA-42 90/10 copper/silver
electrodes in PPM
Calculated Silver Level if using
the CLA-44 80/20 copper/silver
electrodes in PPM
0.05
0.0056
0.0125
0.10
0.0111
0.0250
0.15
0.0167
0.0375
0.20
0.0222
0.0500
0.30
0.0333
0.0750
0.50
0.0556
0.1250
0.70
0.778
0.1750
1.00
0.1111
0.2500
When all of the above steps have been completed, it is time to start up the
system. Open all valves and turn the power on. Check for water leaks and
all electrical connections for proper and firm connections. Remove the clear
protective sheet from the control unit. When starting the system, the
Clearwater Enviro Technologies, Inc. logo should first appear, followed by
a three-digit number. To get better acquainted with the unit, turn the
control knob counter-clockwise till the unit reads “OFF”.
Once you have obtained the desired reading, the setting will most likely remain at that value the entire season, or close
to it. The trick is getting the desired reading quickly.
By turning the control knob clockwise, the unit will read a three-digit number. These are actually
milliamp (mA)
readouts
and go from
005
to
600
in 5 mA increments. If the readout does not go all the way to 600, chances are the TDS
level is not over 300 or so. Do not cause any alarm or add salt to the pool unless you are
not able to obtain the desired
ion level (more in this section to follow).
Copper Level
F.) Starting Up the System
Setting the Control Knob to the Desired Level