Steel plumbing.
Never install the electrodes on steel piping. Cut out a section of pipe and replace with PVC pipe
where the electrodes are installed.
11.)
Improper installation.
Have the electrodes been installed on the return line? Make sure the electrode chamber is
angled downward so that the chamber is full of water and no airpocket can get in there. Check all wires for proper
connections.
12.)
Indicator lights do not come on.
Make sure the unit has been installed properly to the correct voltage. Make sure
power is going to the main source. Check fuse inside unit.
To check the fuse, first open up the unit: TURN OFF ALL POWER FIRST!!!!
1.) Open up the clear lid.
2.) Unscrew the four (4) screws holding the faceplate assembly in place.
3.) Lift up faceplate assembly and flip over.
4.) Locate fuse and check. (see page 10 for photo)
5.) Replace fuse if blown (5mm x 20mm 20V, 1/4A, fast acting)
6.) Mount faceplate assembly back in place
7.) Tighten four (4) screws to secure.
If the fuse was blown, try to determine what happened. If this repeats again, you may need to install a surge protector
before the power source.
If the fuse was not blown, and you get no output at all, check the back or the circuit board for anything unusual - loose
parts, burn marks, etc. If this is the case, call your
dealer
or
Clearwater Enviro Tech
direct to return the circuit board.
YOU MUST OBTAIN AN "RMA" NUMBER BEFORE RETURNING ANY EQUIPMENT FOR REPAIR.
This unit was designed for easy removal of the circuit board. See next section for details to remove circuit board.
THERE
IS NO NEED TO RETURN THE ENTIRE CONTROL BOX. THIS WILL SAVE TIME AND SHIPPING COSTS
AT BOTH ENDS.