background image

7

5. Attentions

Please read the manual carefully before use.
Please keep the manual after reading.

1.  Please place the machine in a safe place where it is not easily to be kicked down.

2.    Please turn off power and remove the plug from the socket, when the machine is 

not used for a long time. If you need to turn off power, make sure to pull out the 
plug part, and do not directly pull the power cord out.

3.     Do not continue to use, when the machine is broken or damaged due to other 

reasons, or the product operation fails. Do not place the power cord near or on a 
hot surface.

4.   Please close the doors and windows during the machine operation.

5.   Do not use the machine until it is properly installed.

6.   Do not use the machine in the environment of flammable or explosive gas.

7.     Do not leave the machine in the rain, or use it near water, such as laundry  

 

or other wet places.

8.   The machine must be placed vertically for use.

9.     Do not allow foreign matters to enter the air inlet or air outlet to avoid electric 

shock, fire or damage to the machine. Do not cover the machine.

10.  Place the machine close to the power outlet, and avoid using extension cable.

11.    If the plug and socket are loose, it may cause overheating or plug distortion.  

Please contact a qualified electrician to replace the loose or damaged socket.

12.    If the power cord is damaged, it must be replaced by the manufacturer, other 

service office or qualified personnel to avoid danger. Do not continue to use. Do 
not sit, stand or place heavy objects on the machine.

13.  Disconnect the power before repairing.

Summary of Contents for SafeAirFlow4

Page 1: ...1 ENGLISH User s Manual www SafeAirFlow com ...

Page 2: ...2 ...

Page 3: ...erformance Parameters 4 Application and Scope 5 Attentions 6 Installation Method 7 Placement Instructions 8 Usage Start machine Air volume touch control 9 Maintenance Clean primary filter Clean top grill Clean and maintain sensor 10 Replace filter element 11 FAQ and Troubleshooting 2 2 3 3 4 4 5 6 7 8 8 8 8 8 9 9 10 10 ...

Page 4: ...tals outpatient operating rooms ICUs protective isolation wards treatment rooms dispensing rooms etc It can be used in Class II III and IV medical environments The product can sterilize instantly under the condition of coexistence of man and machine reducing the risk of nosocomial infection and improving the level of sensory control SafeAirFlow4 elements Primary filter Filter element cover UV C fi...

Page 5: ...ay Display the remaining time of the filter element at the end of its service life Air quality indicator Air quality respectively corresponds to green yellow orange and red Green excellent air quality Yellow good air quality Orange average air quality Red poor air quality Operating mode AUTO automatic mode For improving indoor air quality fan speed is adjusted according to PM2 5 dust content which...

Page 6: ...d in Class II III and IV medical environment Such as waiting rooms treatment rooms patient rooms etc SafeAirFlow4 390 x 420 x 630 mm about 15 kg 120 W 4x 24 Watt UV C PHILIPS PL L 50 Hz 2400 m3 depening on contamination level 68 dB A Mobile free of installation Model Size L x W x H Net weight Input power W Lamps Rated frequency Applicable space Noise Installation ...

Page 7: ...operly installed 6 Do not use the machine in the environment of flammable or explosive gas 7 Do not leave the machine in the rain or use it near water such as laundry or other wet places 8 The machine must be placed vertically for use 9 Do not allow foreign matters to enter the air inlet or air outlet to avoid electric shock fire or damage to the machine Do not cover the machine 10 Place the machi...

Page 8: ...ips and then pull the primary filter screen toward you to remove it b Open the cover of filter element pull the buckle toward you and take it off d Install the filter element as the direction indicated on it Connect the reserved power cable of the filter element chamber to the UV module Please note that the power cord has voltage 220 V do not connect the machine power before connecting 1 2 ...

Page 9: ...ilter screen back Repeat the above steps to install the filter element on the other side f Put the cover of filter element back In order to get better performance the air inlet should be kept at certain distance from the walls and other obstructions during using Make sure that the side with the two fixing clips is facing to you and that all hooks of the primary filter screen are properly connected...

Page 10: ...n can be taken out and cleaned by hand in warm water Pay attention to clean gently After the primary filter screen is completely dried it can be installed back into the machine Recommende to clean it every month b Press the mode switch button The machine enters AUTO operation mode Switch between AUTO and ECO mode Air volume adjustment The machine enters AUTO operation mode Do not carry out mainten...

Page 11: ...he sensor c Close the sensor cover The back cover of the dust sensor is located at the rear side of the machine Open the back cover by pushing up the groove with your fingers When cleaning use a dry cotton swab to gently wipe the dust on the sensor It is recommended to clean it every six months If the machine is used in dusty environment please clean it frequently c Reinstall the top grill first i...

Page 12: ...heck if the power plug is connected properly If the filter element cover and the top grill are not closed properly the machine cannot work The screen has no display Please check if the machine is powered on Please confirm if the power button is pressed you should hear a beep after pressing the button UV C light does not work Please turn off power and open the filter cover and check if the disinfec...