background image

6

#

Inlet cap

 

Impellor

 chamber O-ring

Front shell 

Rear bearing

Back shell 

Impellor

 lid

Rotor

 

Motor body

See Figure 1.

3. Product description.

3.1 Product’s aims.

The product you bought is a magnetic drive centrifugal pump, operated by a watertight synchronous motor, 
and is the most reliable small pump on the market.

3.2 Structure.

4. Technical data and characteristics.

See Table 2 in Figure 2.
The hydraulic parts used for the building of the system which shall include the product modify the performance 
(head and flowrate) of the product.

5. Installation.

5.1 Storage characteristics and conditions.

The product must be stored in a dry place, protected from weather.

5.2 Transport.

Handle the product with care to avoid damages.

5.3 Positioning.

The product must be submersed in a home pond, in an easily accessed position.
It is advisable to take the following into account:

Dimensions and position of hydraulic parts.

• 

Necessary free space.

• 

Cable position.

• 

Location of the power supply (power outlet).

• 

Support and its location.

• 

5.4 Connection and commissioning.

The product must be installed and operated by individuals with appropriate training. The electrical system 
must meet current international and/or national regulations.
The product must be connected to a power outlet equipped with a residual current device, with a sensitivity 
not lower than 30 [mA]. Before starting the product, check that your electrical system is equipped with this 
safety device; if necessary, consult a technician.
Check that the product is compatible with the power supply it shall be connected to.
The power outlet must be appropriately far from the water, but easily accessible, so that the product can be 
stopped quickly in failure situations. It is strictly forbidden to cut the wire and /or replace the power plug.
The power supply wire must be positioned so as to prevent possible damages, such as torsion and/or cuts.

5.5 Reinstallation and reuse.

Clean the product and the moving parts accurately before stopping the product for a while, such as, for 
instance, during the winter months. Do not lubricate and/or use detergents and chemical cleaning products.

5.6 Disassembly and disposal.

Collecting recyclable material, both those used for packaging (cardboard, nylon, etc.) and those replaced 
during  routine  and  extraordinary  maintenance  is  recommended.  Suitable  collection  of  waste  material  for 
recycling,  processing  and  environmentally  compatible  disposal  contributes  in  avoiding  possible  negative 
effects on the environment and health and promote the reuse and/or recycling of product materials.
Illicit product disposal by the user may be punishable by current international and/or national laws.

5.6.1 Collection of electric/electronic waste materials.

EU directive 2002/96/EC classifies this product as an electrical or electronic tool.
The barred bin symbol on the equipment or packaging indicates that the product must be separated from 
other waste at the end of its working life. Therefore, the user must take equipment to electronic and electro-
technical waste collection centres at the end of its working life or return it to the dealer when purchasing 
similar  new  equipment,  on  a  one  to  one  basis.  Suitable  collection  of  decommissioned  equipment  for 
recycling,  processing  and  environmentally  compatible  disposal  contributes  in  avoiding  possible  negative 
effects on the environment and health and promote the reuse and/or recycling of device materials. Illicit 
product disposal by the user may be punishable by current national laws.

Summary of Contents for ETERNITY Series

Page 1: ...3000 ETERNITY 2000 ETERNITY 1400 ETERNITY 800 Customer Manual Index 1 Overview 4 2 General instructions and information for the user 5 3 Product description 6 4 Technical data and characteristics 6 5...

Page 2: ...2 ETERNITY 9000 7000 ETERNITY 3000 4000 ETERNITY 1400 2000 ETERNITY 800 Figure 1 ETERNITY 9000 7000 ETERNITY 3000 4000 ETERNITY 1400 2000 ETERNITY 800 Figure 2...

Page 3: ...ERNITY 7000 130 6500 3 9 2 58 kg 124 mm 111 mm 243 mm ETERNITY 4000 65 4000 3 7 2 16 kg 126 mm 111 mm 223 mm ETERNITY 3000 60 3000 3 2 2 16 kg 126 mm 111 mm 223 mm ETERNITY 2000 40 2000 2 3 1 80 kg 10...

Page 4: ...jects Figure 1 6 Dry operation means the pump s operation without water Rotor it indicates all the rotating components of the pump Figure 1 4 Impellor The front part of the rotor made up of a plastic...

Page 5: ...as been followed correctly 2 1 3 Limitations i This guarantee applies exclusively to sales to consumers consumers being the people who buy the product for purposes that do not concern his or her profe...

Page 6: ...o that the product can be stopped quickly in failure situations It is strictly forbidden to cut the wire and or replace the power plug The power supply wire must be positioned so as to prevent possibl...

Page 7: ...environmental limits The product cannot enliven water destined to the human consumption Maximum water temperature 35 C Minimum water temperature 4 C Maximum depth of immersion 1 m Minimum depth of imm...

Page 8: ...cident and or negligence Dispose of the product Damaged rotor and or bearing plastic components Wear Replace the rotor and or bearing Please consult a skilled technician 7 1 2 Rotor cleaning and or re...