75587
HMS-4X Link Group Member does not re-link following change to IP Address:
Following a change to the IP address the Master may take time to re-correlate mDNS and the
updated IP address.
Workaround:
Reboot the Link Group Master
75633
HMS-4X Link Member
–
Changing Channel names from front panel:
Changing a Channel name on the front panel of HMS-4X configured will only change the name of
the Channel for endpoints connected to the HMS-4X Link Member. The change will not
propagate to the Link Master and the rest of the system.
Workaround:
Change the Channel name on the HMS-4X Link Master or in the CCM.
71545
Active GPI states not maintained during configuration change;
When the properties of a button are change while assigned a GPI that is made, the button state
may not read the GPI state until the GPI state is changed.
Workaround:
Toggle the GPI following a configuration change.
n/a
HMS does not find an inserted USB key:
In rare instances the HMS may not be able to read older or larger USB memory devices
connected to the front panel USB A connector for firmware upgrades or config backups.
Workaround:
Suggest trying a different or newer USB stick or formatting. 16Gb or smaller.