Encore TWC-703 Adapter
3.2
Power Injection Mode
This optional mode is identical to Normal Mode but uses an external PSU (453G023) to add
power to the TWC-703 Adapter's TW output to prevent draining power from the Encore Master
Station or PSU.
Note:
The PSU is not included with the TWC-703 Adapter, and must be ordered separately.
Note:
A typical system connection example is given below.
3.3
Stand-Alone Mode
This mode enables you to have a very small 2-channel TW partyline system by using the
external PSU (453G023).
Note:
The PSU is not included with the TWC-703 Adapter, and must be ordered separately.
A typical system connection example is given below.
3.3.1
To connect and operate the TWC-703 in Stand-Alone Mode.
1. Disconnect any Clear-Com power lines from the front panel of the adapter.
Note:
In case of unstable audio performance and level fluctuations, ensure that J8 and J9
internal switches are
ON
. For default settings, see
.
2. Connect the external power supply to the rear panel of the adapter.
3. Connect RS703 beltpacks. You can connect up to 12 beltpacks.
Note:
RS703 Beltpacks must be configured for TW using DIP switches.
Page 14