background image

(866) 455-2135

 

[email protected]

 

www.cleanleaf.com

 

SPECIFICATIONS OF THE CLEANLEAF 

25

00 SERIES 

Cabinet:16 GA Cold ROLLED Steel 

Finish: White Chemical Resistant Powder Coating Paint 

Size:

    

Standard - 

59

"L x 2

4

"W x 

24

"H 

Units: CL

25

00-C

F

 - 

 10lb Carbon After Filters

CL

25

00-CF

P

 - 

(

4

) 10lb. Carbon After 

Filters

 CL

25

00-CF

-PCO

 - 

Photocatalytic 

Oxidizer CL2500-HE - HEPA Filter

Shipping CL

25

00-C

F

 - 

160

 lbs 

Weight:   

 

CL

25

00-CF

P

 - 

19

lbs

 CL2500-CF-PCO - 165 lbs 

 CL2500-HE - 190 lbs

Power: 115V 60Hz Single Phase 

10.2

 Amps 

Capacity: CL

25

00-C

F

 - 

240

0 ACFM 

CL

25

00-CF

P

 - 

180

0

 ACFM 

CL

25

00-CF

-

P

CO 

-

 24

00 ACFM

 

CL2500-HE

 

 - 1800 ACFM

Motor: 

PSC Type 3/4hp Direct Drive with Thermal Overload

Switch: 

Two

 Speed Switch 

Blower: 

10 by 10 Direct Drive Centrifugal Forward Curve

Grille: 

Four-way Individually Adjustable Blades 

Bag Filter: 

24" x 24" x 15" 95% 12 Pocket 

 

Pre Filter: 

24" x 24" x 4" Pleated 

Options: Silencer Reduces Noise by 6-8 Decibels 

Magnehelic Pressure Gage 0-2" W.C. 
“L” Mounting Brackets 
Eyebolts (Installed on unit at the Factory)

Strut Channel – 28” Hanging Brackets for Mounting 

Drain Plug – Oil / Mist Drain via Hose Barb Fitting

 

Warranty: Three Years on all parts. (filters not included) 

Summary of Contents for CL2500 Series

Page 1: ...AS DIRECTED ALL THE POTENTIAL HAZARDS OF DUST AND MIST CONTROL SYSTEMS AND EQUIPMENT ARE IMPOSSIBLE TO LIST THEREFORE OBTAIN THE SERVICES OF A PROFESSIONAL INSTALLER A FIRE PROTECTION EXPERT SHOULD BE...

Page 2: ...z Single Phase 10 2 Amps Capacity CL2500 CF 2400 ACFM CL2500 CFP 1800 ACFM CL2500 CF PCO 2400 ACFM CL2500 HE 1800 ACFM Motor PSC Type 3 4hp Direct Drive with Thermal Overload Switch Two Speed Switch B...

Page 3: ...xplosion relief vents are required on some applications Consult with an insurance underwriter or an NFPA manual to determine proper vent size ratio Dust or mist collectors must be located outdoors unl...

Page 4: ...may apply in your particular area If there are no local requirements you should follow the National requirements If the optional Drain Plug was installed in your unit you can connect an appropriate 3...

Page 5: ...866 455 2135 info cleanleaf com www cleanleaf com CLEANLEAF CL2500 Installation Mounting Options Option 1 Mounting w Eye Bolts Option 2 Mounting Strut Channel...

Page 6: ...866 455 2135 info cleanleaf com www cleanleaf com Option 3 Wall Mounting w L Brackets Bolt to Mounting Bracket Bolt to Wall L Brackets should be 6 from the ends of the unit...

Page 7: ...hen it is time to change main filter The reading may vary depending upon the contaminants Please consult your Sales Engineer for further information FILTERS All units are equipped with replaceable typ...

Page 8: ...866 455 2135 info cleanleaf com www cleanleaf com CL2500 Wiring Diagram CL2500 w 3 Speed Switch Wiring Diagram...

Page 9: ...OR MOUNT 5 30 2000 Two Speed SWITCH 6 30 2002 12 POWER CORD 7 30 3000 4 WAY ADJUSTABLE LOUVER CL2500 Replacement Filters ITEM PART DESCRIPTION 8 CLF 4404 24 x 24 x 4 Pleated Prefilter 9 CLF PCO Photoc...

Page 10: ...and open all dampers if installed Check ducting for blockage if installed Check for dirty or blocked filters refer to Maintenance section Check rotation of fan Excess vibration Check structural suppo...

Page 11: ...nameplate current rating Check motor load If the motor has manual re set thermal protector check if it has been tripped Motor may be overloaded Reduce load Increase motor size If permanent split capa...

Page 12: ...r horsepower motor Reduce system restrictions blower Increase system restriction blower fan Motor overheats while running under load Overload Reduce load increase motor size Dirt preventing ventilatio...