GROUNDING INSTRUCTIONS - 120 VOLT 

 
Improper use of the grounding plug can result in 
a risk of electric shock. 
 
Electrical equipment must be grounded. If it 
should malfunction or breakdown, grounding 
provides a path of least resistance for electrical 
current to reduce the risk of electric shock. 
 
The unit is equipped with a cord having 
equipment grounding conductor and grounding 
plug. The plug must be inserted into an 

appropriate outlet that is properly installed and 
grounded in accordance with all local codes and 
ordinances. 
 
If repair or replacement is necessary, DO NOT 
connect the grounded wire to either flat blade 
terminal. The wire with insulation having an 
outer surface that is green with or without yellow 
stripes is the grounding wire. 

 

GROUNDING METHODS 

 
This electric equipment is for use on a nominal 
120-volt circuit and has a grounded plug that 
looks like the plug illustrated in (Fig. A). A 
temporary adaptor that looks like the adaptor 
illustrated in (Fig. B & C) may be used to 
connect this plug to a 2-pole receptacle as 
shown in (Fig. B) if a properly grounded outlet is 
not available. 
 

The temporary adaptor should be used only until 
a properly grounded outlet (Fig. A) can be 
installed by a qualified electrician. The green 
color rigid ear, lug or the like extending from the 
adaptor must be connected to a permanent 
ground such as a properly grounded outlet box 
cover. Whenever the adaptor is used, it must be 
held in place by a metal screw. 

 
 

 
 
Note:  In Canada, the use of a temporary adaptor is not permitted by the Canadian Electrical Code. 

Summary of Contents for Pelican FloodVac HBP20FV

Page 1: ...loodVac unit Model HBP20FV It provides necessary operation and maintenance instructions 20 GAL SINGLE VAC FLOOD VACUUM READ AND FOLLOW ALL INSTRUCTIONS WARNINGS AND CAUTIONS BEFORE AND WHEN USING THIS EXTRACTOR All information and specifications printed in this manual are current at the time of printing However because of Cleanfix s policy of continual product improvement we reserve the right to m...

Page 2: ...push the RESET button more than twice Have a qualified service person check out the unit A GFCI does not protect against circuit overloads and short circuits Do not run waste pump dry as it will damage the seals The vacuum is intended for WET pick up only Do not use as a dry vacuum Do not operate the machine where explosive vapors or flammable materials exist Do not use where oxygen and anesthetic...

Page 3: ...her flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire GROUNDING METHODS This electric equipment is for use on a nominal 120 volt circuit and has a grounded plug that looks like the plug illustrated in Fig A A temporary adaptor that looks like the adaptor illustrated in Fig B C may be used to connect this plug to ...

Page 4: ...switch lighted when it is on 3 1 1 2 vacuum hose adaptor 4 Drain valve for recovery tank Pull T Handle up to open Drain valve must be closed after each use Install drain elbow upon receipt of the unit 5 Latches to motor compartment Latches must be secured when using the machine 6 GFCI Ground Fault Circuit Interrupter red RESET button black TEST button Occasionally press the TEST button then RESET ...

Page 5: ... St Wyckoff NJ 07481 All rights reserved Content is subject to change 5 FUNCTIONAL PARTS AND ACCESSORIES cont Rear view 9 1 1 2 discharge hose adaptor A discharge hose must be connected at the discharge adapter when discharge pump is turned on 10 Power cord 9 10 ...

Page 6: ...mpty out recovered waste into a bucket Remove lint bag and turn it inside out to clean Rinse the recovery tank with clean water Replace lint bag TROUBLESHOOTING Symptom No power to the machine Problem GFCI RESET button popped out Solution Lift cover and push RESET red button If the RESET button pops out immediately the second time do not attempt to RESET again Have a qualified service technician c...

Page 7: ... pump out will not start or run Problem GFCI reset button popping out only when waste pump is turned on indicates damage to pump seal or internal cable connection leak Solution Have a qualified pump service shop repair the pump If the pump is defective replace pump 12305 Problem Defective rocker switch Solution Replace black DPDT rocker switch 12276 or lighted rocker switch 12027 Problem Debris un...

Page 8: ...hes wheels casters glides clutches cords filters filter bags gaskets hoses rectifiers switches float switches valves squeegees bearings pulleys relays actuating cables wheels tires vacuum cleaner attachments The purchaser is assured that meticulous care has been exercised in the selection assembling and testing of these parts and components before shipping No warranty is extended for machine finis...

Reviews: