JINHCN05 RevE 22/07/14
S
Ø
nderskoven Inset 5
Technical Specification
SØNDERSKOVEN INSET 5
Cleanburn Stoves, Unit 6,
Old Mill Industrial Estate, EX5 4RJ
BS/EN 13229
UKAS# 0692
Stove Mass: 100 kg
NOMINAL OUTPUT: 4.9 KW
CO Emission at 13% O
2
: 0.19%
Mean Flue Gas Temperature: 292°C
EFFICIENCY: 77.1%
Flue Gas Mass Flow: 4.3 g/s
Minimum clearance to combustible material
Top of Fire Surround:
200mm
Side of Fire Surround:
150mm
Side Wall:
300mm
This appliance is suitable for intermittent burning
This appliance is not suitable for use in a shared flue
Read and follow the operating instructions
Use only recommended fuels
This stove has been designed and assembled so that it may be used to burn wood logs in a Smoke
Control Area.
Find out if you are in a Smoke Control Area by contacting your Local Authority.
The S
Ø
nderskoven Inset 5 has been fitted with a permanent bypass that prevents closure of the
secondary air slider. Removal of this will lead to the appliance potentially causing smoke emissions.
Without the permanent bypass in place the appliance is not an exempt appliance and so may leave
the householder liable for a fine up to £1000.
12