Summary of Contents for PH200

Page 1: ...CLEAN PH200 PH500 pH mV ORP Ion Versatile Water Analysis Meter CLEAN INSTRUMENTS CO LTD 2F No 140 Zhongxiao St Zhonghe Dist New Taipei City Taiwan www cleaninst com E mail CS cleaninst com ...

Page 2: ...www cleaninst com MODE ESC CAL INFO MI SET ENT HOLD MR PH200 MODE ESC CAL INFO MI SET ENT HOLD MR PH500 pH mV ORP Ion Temp CLEAN PH200 PH500 Versatile Water Analysis Meter ...

Page 3: ...ion P02 Manual Temperature setting P03 Temperature Offset setting P04 Auto Lock Function setting P05 Prompt tone setting optional P06 Auto Power Off Setting P07 Clearing Memory Function P08 Reverting to Factory Default Setting 5 4 2 ORP set up 5 4 3 Ion set up P01 Measuring unit setting P02 Calibration point setting P03 Ionic valence setting 5 5 Calibration Mode 5 6 Measurement Mode 5 7 Storage of...

Page 4: ...01 ...

Page 5: ...02 BNC Temperature M SET ENT HOLD MR PH200 ...

Page 6: ...03 ...

Page 7: ...D Auto lock 6 C F Temperature 7 ATC Automatic Temperature Compensation 8 PH mV ORP Ion ppm mg L Measurement mode Unit of Measurement 9 STD Standard solutions 10 mV Zero drift mV indicator or Ion sensor slope 11 Uncalibrated meter is 0 and twinkling When sensor slope is 65 twinkling Display 4 Appearance ...

Page 8: ... Offset Menu item Buffer Solution Buffer kinds Reset to factory defaults Save Data On Off No Yes Temperature value Over Temperature value Under Full Data Storage Measuring Value Over Measuring Value Under Battery Error Ion concentration unit selection Ion calibration Points Ionic valence 10 of the fourth power 10000 10 of the fifth power 100000 Display Character Table ATC ...

Page 9: ...ble Optional HOLD Auto Lock function Temperature offset adjust 200 sets of measuring data storage Auto power off if no operations in 10 minutes Optional 2 1 5V 7AAA batteries Long battery life span CLEAN PH200 PH500 series products with precise and practical design concept simple operation powerful functions complete measuring parameters wide measurement range Four sets with 11 points buffer combi...

Page 10: ...99mg L ppm 0 001 0 01 0 1 1 mg L ppm 1 1LSD 1 valence 2 1LSD 2 valence 3 1LSD 3 valence 40 0 125 0 40 0 257 0 F 0 1 C 0 1 F 0 2 C 0 1 F 2 1 5V 7AAA batteries 1 68 4 01 7 00 10 01 US 2 00 4 01 7 00 9 21 11 00 EU 1 68 4 00 6 86 9 18 12 46 CN 1 68 4 01 6 86 9 18 JP 5 C 60 C Relative humidity 90 200 sets 94 190 35mm W L H 250g pH ORP Ion Temperat ure Battery pH Buffer Kinds Others 5 1 Technical Specif...

Page 11: ...compensation 5 Prompt tone ON OFF 6 Hold Auto Lock 7 ON OFF Auto power off 8 Battery power 5 2 Model and Function pH Buffer kinds Manual temperature Temperature offset Auto Lock Prompt tone Auto power off Clear the saved data Revert to factory default P 01 P 02 P 03 P 04 P 05 P 06 P 07 P 08 Ion Switch measuring unit Calibration point Ionic valence setting ORP ...

Page 12: ...p step Press to enter electrode calibration mode In P 01 press to enter Press to select among B1 B2 B3 B4 buffer kinds Press to confirm Please refer to above description steps to set up P 01 You can go to next parameter setting by pressing or pressing key to quit and go back to measurement mode B1 1 68 4 01 7 00 10 01 US B2 2 00 4 01 7 00 9 21 11 00 EU B3 1 68 4 00 6 86 9 18 12 46 CN B4 1 68 4 01 ...

Page 13: ...0 0 125 0 40 0 257 0 F Please refer to above description steps to set up P 02 You can go to next parameter setting by pressing or pressing key to quit and go back to measurement mode Note 1 Please make sure the Temperature Electrode is UNPLUGGED when manual Temperature compensation Otherwise the unit will display Err and go back to the set up menu for fresh operation 2 It is not working to unplug ...

Page 14: ...ou can go to next parameter setting by pressing or pressing key to quit and go back to measurement mode Note 1 Please make sure the Temperature Electrode is PLUGGED when Temperature Offset setting Otherwise the unit will display Err and go back to the set up menu for fresh operation The ATC will be displayed beneath the main screen the screen normally 2 It is not working to plug the Temperature El...

Page 15: ...ameter setting by pressing or pressing key to quit and go back to measurement mode P 04 Auto Lock Function setting 12 P 05 Prompt tone setting optional After entering P 05 you can select ON or OFF the prompt tone by pressing If the prompt tone is ON you will hear the Beep tone after the reading had stabilized when in calibration Please refer to above description steps to set up P 05 You can go to ...

Page 16: ...ressing or pressing key to quit and go back to measurement mode After entering P 06 you can select ON or OFF the Auto Power Off by pressing If the Auto Power Off is ON the meter will power off if no operation in 10mins Please refer to above description steps to set up P 06 You can go to next parameter setting by pressing or pressing key to quit and go back to measurement mode P 07 Clearing Memory ...

Page 17: ...e settings will lost forever The unit will restart at the same time Please refer to above description steps to set up P 08 You can go to next parameter setting by pressing or pressing key to quit and go back to measurement mode Note 1 During setting you can press key to quit setting whenever necessary 2 During setting you can adjust anything twinkling by pressing If it is the data twinkling you ca...

Page 18: ... switch between measuring unit mg L and ppm by pressing Confirm your setting by pressing Please refer to above description steps to set up P 01 You can go to next parameter setting by pressing or pressing key to quit and go back to measurement mode P 04 Auto Lock Function setting P 05 Prompt tone setting optional P 06 Auto Power Off Setting P 07 Reverting to Factory Default Setting ...

Page 19: ... pressing or pressing key to quit and go back to measurement mode Please refer to above description steps to set up P 02 After entering P 03 you can select 1 valence 2 valence 3 valence by pressing Confirm your setting by pressing Please refer to above description steps to set up P 03 You can go to next parameter setting by pressing or pressing key to quit and go back to measurement mode Below is ...

Page 20: ...d You can go next to third point calibration or fourth point calibration You can also press key go back to measurement mode To check the calibration results long press for 3 seconds Note During the calibration process you can also press key to terminate calibration process and back to measurement mode Calibrated points are already saved If Err shows when in calibration could be the following reaso...

Page 21: ...adjust the corresponding concentration value at the bottom row 0 10 1 10 100 1000 104 105 mg L Press to confirm First point calibration is completed Go to second point calibration Change the standard solution When the value is stable and display press keys to adjust the corresponding concentration value at the bottom row 0 10 1 10 100 1000 104 105 mg L Press to confirm Second point calibration is ...

Page 22: ... shows the actual temperature upper right corner You can refer to the P 02 Temperature Offset setting if a revision on the temperature is required 2 If ATC is not shown on the screen means the temperature electrode is disconnected and is manual temperature compensation Factory default is 25 C You can refer to Manual temperature setting to adjust the temperature 3 The measuring value is stabilized ...

Page 23: ... data The screen will show OVER if more than 200 sets reminds you the memory card is full 2 Enter into setting mode P 07 if you need to delete the saved data forever You can refer to Clearing memory function 1 Press to enter into the browse on the data storage the Lot no will be shown and data twinkling Press to check all the saved data Press to go back to measuring mode If showed NONE means no da...

Page 24: ...press to enter into Setting parameter when in measurement mode Press to check through all the Calibration parameters and Setting parameter 2 Press to quit and go back to measurement mode 5 8 Browse on Setting Parameters 21 Sensor slope and Zero offset Ion sensor slope ...

Page 25: ...ace P 01 P 02 P 04 P 05 P 06 Item Standard Solution Temperature Auto Lock Prompt tone setting Auto power off Backlight Factory Defaults B1 1 68 4 01 7 00 10 01 US Manual Temperature Compensation 25 C OFF OFF No configuration ON OFF 5 9 APPENDIX ...

Page 26: ...ease nclude date requiring the reason of return Instruments must be carefully packed to prevent damage in shipment and insured against possible damage or loss CLEAN Instruments will not be responsible for any damage resulting from careless or insufficient packing Warning Damage as a result of inadequate packaging is the User distributor s responsibility Please follow the guidelines below before tr...