background image

User Manual

1-YEAR 

MANUFACTURER 

WARRANTY

READ ALL INSTRUCTIONS BEFORE USING, OR SERVICING, THIS EQUIPMENT. KEEP THIS 

MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS.
English (Original Instructions)

2-Part 
Concentrate
Foamer

Reset 

Foamer

Summary of Contents for Athena Perafoam

Page 1: ...R WARRANTY READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS EQUIPMENT KEEP THIS MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS English Original Instructions 2 Part Concentrate Foamer Reset Foamer ...

Page 2: ... Athena Reset Foamer 1 Safety 3 2 Product Overview 5 Product Requirements 5 Product Specifications 5 Product Components 6 3 Operation 8 4 Maintenance 10 5 Troubleshooting 11 6 Parts 12 7 Warranty 14 Contents ...

Page 3: ...ution and cause serious injury such as burns rashes eye damage throat or lung damage and death Always depressurize and clean the unit after each use Release any remaining air pressure by twisting the pressure relief valve to the right turn Never leave the unit unattended while pressurized Using the unit with fluid temperatures above 100 F 37 77 C may result in scalding burns serious injury or deat...

Page 4: ...t in diminished performance and damage to the unit Do not use an air lubricator before the unit Moisture in the air lines will damage the pump and diminish the pumps life The air must be filtered clean dry and free of moisture If needed install an air dryer before the unit PROTECT THE ENVIRONMENT Please dispose of packaging materials old machine components and hazardous fluids in an environmentall...

Page 5: ...ce department Power type Compressed air Chemical pickup type Draws from concentrated product Dilution ratio 1 oz 29 57 ml of each chemical per 1 gallon 3 8 liters of water Number of products unit can draw from Two products simultaneously Capacity 15 gallons 56 8 liters of water 5 gallons 18 9 liters of Athena PERAFOAM 5 gallons 18 9 liters of Athena RESET Discharge line length diameter 50 ft 15 2 ...

Page 6: ...etering tips 3 Dual injector 4 Suction lines 5 Quick change pump 6 Flow control valve includes black knob 7 Air regulator 8 Air pressure gauge 9 Check valves 10 In line strainer 11 Suction line valve Product components Before you begin get to know the Athena Reset Foamer components that you will need to use adjust or assemble ...

Page 7: ...set Foamer 14 18 6 Tank assembly Front view 12 Tank assembly Back view 16 13 15 4 4 17 11 12 Discharge ball valve 13 Foam wand with spray tip 14 Hinged cap assembly 15 Chemical jug 16 Tank 17 Drain plug 18 Air fitting ...

Page 8: ...e is open to allow fluid into the suction line 5 With the discharge ball valve in the closed position plug an air line into the air fitting 6 Slowly open the discharge ball valve to begin foaming The discharge ball valve should be completely open while foaming 7 While the unit is running and discharging product adjust the flow control valve as needed to regulate the wetness or dryness of the foam ...

Page 9: ...ontains water 12 Activate the unit and allow it to run for 2 4 minutes or until all chemical has been flushed from the system 13 Disconnect the air line from the air fitting 14 Open the discharge ball valve to relieve any pressure remaining in the system 15 Close the ball valve after all pressure has been relieved from the system Store the unit with the discharge ball valve in the closed position ...

Page 10: ...l void the warranty To keep your foam unit operating properly periodically perform the following maintenance procedures Inspect the pump for wear and leaks Inspect all hoses for leaks or excessive wear Make sure all hose clamps and push fittings are in good condition and properly secured Replace the filter located within the air regulator as needed Clean by unthreading the air regulator bowl from ...

Page 11: ...replace as needed To prevent damage to the unit the strainer must always be used Check the air compressor supplying the unit If the pressure is less than 40 psi turn the unit off until the compressor can catch up If the air supply is 50 psi 3 4 bar or above check the air gauge which should read near 50 psi 3 4 bar If the air gauge reads more or less than 50 psi 3 4 bar adjust the pressure by turni...

Page 12: ...80150SS CL P203CT FS CL H14C CL H38C CL QCPP M HAST CL QCPP14HB HAST CL SSW1210FM CL H38B F Wand assembly Back Plate CL J5BKS Jug assembly CL J5 CL AG100 CL CV38 AP CL R25 CL JC35B TAV CL DP A CL TANK 15N C A CL CST5SS L CL CST5SS CL H14B F CL H38B F CL HBSSEL1438 CL HHPB3414 CL PVCV34FM CL SCI 125X2 CL P56K CL STR38 IL CL CV38 AP ...

Page 13: ...less ball valve welded nut CL J5 5 Gallon natural jug CL J5BKS 5 Gallon natural jug black cap suction CL JC35B TAV Black 3 5 in one way vented cap polypropylene EPDM gasket and check valve bead chain tether assembly CL NV14Y Flow control valve includes black knob CL Orange tip Orange metering tip for dema injector CL P203CT FS Foot strainer for the P203CT CL P56K Pump with Kalrez seals includes ho...

Page 14: ...f the appearance of such defect and within the 1 year warranty period If notice is not given by the required deadlines set forth in this paragraph any claim for breach of warranty is waived and Athena shall not be liable Upon receipt of notice of a possible defect in the Goods Athena shall issue instructions for their disposition No Goods shall be returned to Athena without its prior consent Trans...

Page 15: ... used with Athena Perafoam EPA registered peroxyacetic acid Athena Perafoam Foam Adjuvant Easily get full coverage Warning Athena Reset and Athena Perafoam contain hazardous chemicals Always use in accordance with instructions and wear appropriate personal protective equipment PPE Only use the Athena Reset Foamer with Athena Reset and Athena Perafoam ...

Page 16: ...Athena Reset Foamer CL FOAM2 50 ...

Reviews: