- 14 -
Calibration
system
is
wrong
Evaluate and correct it
Medium viscosity is too
high
Improve temperature of product or
lower the viscosity. Increase the
size of pump and pipeline.
Medium cavitations
Increase the pressure of suction,
and shorten the suction pipe.
Flow
becomes
lower
gradually
Check valve leakage
Clean or change the valve
Suction pipe leakage
Find the leakage position and
solute the problem.
Filter is blocked
Disassemble the filter; clean or
change it.
Medium is changed
Check the viscosity and other
parameters
Blowhole of the offering
tank is blocked
Open the blowhole
Flow is
unstable
Suction piping leakage
Find the leakage position and
solute the problem.
Medium cavitations
Increase the pressure of suction and
shorten the suction pipe.
Check valve is blocked
Clean or change it