CLEAN COMFORT DV070 Installation And Operation Manual Download Page 19

WWW.CLEANCOMFORT.COM

19

WARRANTY

IO-DV070

IO-DV070

Limited Warranty

Daikin North America LLC (“Daikin”) warrants as follows: the 

Clean Comfort dehumidifier (“Product”) will be free of material 

defects in workmanship or materials for a period of five (5) years 

following the date of purchase of such Product by the original 

consumer purchaser (“Customer”). 

Limitation of Liability.

 

Customer’s sole and exclusive remedy 

under the above limited warranty, and any implied warranties, 

and Daikin’s entire liability thereunder, shall be for Daikin to 

provide a repaired or replacement Product or component of 

the Product (“Component(s)”), at the sole option of Daikin. 

Refrigerant, piping, supplies, transportation costs, labor costs 

incurred in deinstalling any defective Product or Components,  

or installing the repaired or replacement Product or Components, 

are not included. This disclaimer and exclusion shall apply even 

if the express warranty herein fails of its essential purpose. 

Customer acknowledges that no representative of Daikin 

or any of its affiliates or resellers is authorized to make any 

representation or warranty on behalf of Daikin or any of its 

affiliates or resellers that is not in this warranty. IN NO EVENT 

SHALL DAIKIN, IN CONNECTION WITH THE DESIGN, SALE, 

INSTALLATION, USE, REPAIR, REPLACEMENT OR PERFORMANCE 

OF ANY PRODUCT OR COMPONENTS, OR WRITTEN MATERIAL 

PROVIDED THEREWITH, BE LIABLE, WHETHER FOR BREACH 

OF WARRANTY OR OTHER CONTRACT BREACH, NEGLIGENCE 

OR OTHER TORT, OR ON ANY OTHER LEGAL THEORY, FOR ANY 

SPECIAL, INDIRECT, COLLATERAL OR CONSEQUENTIAL DAMAGES 

OF ANY KIND. Some states and provinces do not allow the 

exclusion or limitation of incidental or consequential damages,  

so the above exclusion may not apply to you.

Other Warranties.

 

THE ABOVE LIMITED WARRANTY IS THE  

SOLE AND EXCLUSIVE EXPRESS WARRANTY PROVIDED WITH 

RESPECT TO THE PRODUCT AND ITS COMPONENTS, AND DAIKIN 

HEREBY LIMITS THE DURATION OF ALL IMPLIED WARRANTIES, 

INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES 

OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

PURPOSE, TO THE DURATION OF THE ABOVE LIMITED WARRANTY. 

Some states and provinces do not allow limitations on how  

long an implied warranty lasts, so the above limitation may  

not apply to you.

Warranty Limitations.

 

The foregoing limited warranty extends 

only to a Customer, and the Customer will not be entitled 

to any remedy hereunder if he or she attempts to assign or 

transfer this warranty. A “defect” under the terms of this limited 

warranty shall not include problems resulting from Customer’s 

or Customer’s employees’, agents’, invitees’ or a third party’s 

misuse, improper installation, improper design of any system in 

which the Product is included, abuse, lack of normal care, failure 

to follow written instructions, tampering, improper repair, or 

freezing, corrosion, acts of nature or other causes not arising 

out of defects in workmanship or material. If a Product or 

Component is replaced while under warranty, the applicable 

limited warranty period shall not be extended beyond the 

warranty time period remaining on the original Product or 

Component. This limited warranty does not cover any costs 

related to changes to a Product or Component that may be 

required by any codes, laws, or regulations that may become 

effective after initial purchase of the Product by Customer.

Customer Responsibilities.

 

In order to make a warranty  

claim, the Customer should call Daikin Consumer Affairs 

at 1-855-239-2665, which will then arrange for Product or 

Component repair or replacement. Warranty claims must be 

made during customary, daytime working hours. As further 

conditions to obtaining warranty coverage hereunder, the 

Customer must present forms of invoices evidencing proof of 

purchase of a Product and return the Product to Daikin if Daikin 

so requests. If the invoice presented does not clearly indicate 

the date of initial purchase by a Customer, the applicable 

Product’s date of manufacture shown on the Product’s rating 

plate will be used instead of the date of initial purchase 

for the purpose of calculating the commencement of the 

applicable warranty period. Repaired or replacement Products 

or Components must be provided by Daikin or a servicer 

authorized by Daikin. If the Product must be shipped to Daikin, 

Customer shall be solely responsible for properly packaging the 

Product, for all freight charges, and for all risk of loss associated 

with shipment. 

Miscellaneous.

 

If any term or condition of this Limited 

Warranty is found by a court of competent jurisdiction to be 

invalid, illegal or otherwise unenforceable, the same shall not 

affect the other terms or conditions hereof or thereof or the 

whole of this Limited Warranty. Any delay or failure by Daikin 

to exercise any right or remedy will not constitute a waiver of 

Daikin to thereafter enforce such rights.

This warranty gives you specific legal rights, and you may  

also have other rights which vary from state to state or  

province to province.

DAIKIN NORTH AMERICA LLC

4201 Lien Rd.  

Madison, Wisconsin 53704

1-855-239-2665

For questions regarding warranty, service, or spare  
parts for this Clean Comfort product please contact  
your installing contractor or a local Daikin representative.  
For technical support, please call 1-855-239-2665.

Summary of Contents for DV070

Page 1: ...nt DV070 dehumidifier utilizes refrigeration to cool the incoming air stream below its dew point This cooled and drier air is then reheated by passing it over the condenser coil Fresh Air Ventilation optional Fresh outdoor air may be ducted to the dehumidifier This provides fresh air to dilute indoor pollutants and replenish oxygen content in the building The amount of fresh air ventilation can be...

Page 2: ...C All rights reserved INTRODUCTION 1 SAFETY PRECAUTIONS 3 INTENDED APPLICATION 3 REGISTRATIONS 3 OPTIONAL PARTS LIST 3 SPECIFICATIONS 3 INSTALLATION 3 Installation Considerations 4 Power Accessibility 4 Space 4 Low Voltage Wiring 4 Back Draft Damper 4 Support Structure and Suspension 4 Electrical Requirements 4 Condensate Water Removal 5 Lifting Condensate 5 Condensate Pump Installation Optional 5...

Page 3: ...3 L Day Efficiency 5 0 pints kWhr 2 4 L kWhr Duct Connections 8 Round inlet 8 Round outlet Air Filter Efficiency MERV 11 Standard 65 Efficient ASHRAE Dust Spot Test Size 9 x 11 x1 Power Cord 9 ft 2 7 m Drain Connection 3 4 Threaded FNPT Refrigerant Type R410a Refer to manufacturer s label for more information INSTALLATION Installation Considerations i CAUTION Prior to installation of the DV070 the...

Page 4: ...gh clearance to handle the unit s overall dimensions as well as the necessary return supply ductwork to the unit Allow a minimum 12 clearance to the side of the unit to allow for filter removal and replacement Low Voltage Wiring Unit location should be in an area where field wiring the remote controls low voltage to the unit will be possible Back Draft Damper It is recommended that a backdraft dam...

Page 5: ... gravity via the drain port Install a 3 4 male NPT adapter to the drain pan It is necessary to assemble your own drain pipe assembly utilizing 3 4 PVC pipe to route the condensate to a drain Pitch grade of drain should be 1 per 10 Take care when installing drain pipe to drain port of the DV070 Use an adjustable wrench to secure the drain port When installing the drain hose make sure the feet are e...

Page 6: ...Isolated Areas Effective dehumidification may require that ducting be branched to isolated stagnant air flow areas Use 8 or larger diameter branch ducting to each of two or three areas use 6 or larger to each of four or more areas Provisions must be made to provide airflow from supply locations to central return location Proper air distribution is important to ensure even humidity control and heat...

Page 7: ...d DV070 return Always select a return from a central location in the home in an area that is always open to the rest of the home Do not use a return from a room that may have its door closed much of the time If the home in which the DV070 is to be installed has an existing forced air HVAC system utilize the HVAC system to make the DV070 installation easier Basement Installation Install a separate ...

Page 8: ...em When installing the DV070 in a home that does not have a forced air HVAC system a single return to the DV070 should be installed in central open area of the home DO NOT locate the return in a bathroom or a kitchen The supplies of the DV070 should be located in the remote areas of the home such as bedrooms den etc Be sure to utilize as many of these remote rooms as possible and not just one loca...

Page 9: ...turning it counter clockwise until it stops Failure to do so may cause the unit to sense the humidity from the wrong area In addition to the built in dehumidistat the DV070 can be equipped with various accessories to control its operation The Clean Comfort DVP 4034748 digital control is recommended The DVP 4034748 allows homeowners the ability to monitor and control relative humidity levels in the...

Page 10: ...DVP 4034748 control or damage to the transformer may result Wiring of Digital Control Circuit Breaker To prevent damage to the 24 volt control transformer the DV070 comes with a resettable circuit breaker Check wiring for any electrical short and repair before resetting breaker Resetting the circuit breaker without correcting the electrical short may result in transformer damage Be sure to check t...

Page 11: ...e 24VAC Max Current DMP COMP FAN 1 AMP each Humidity Range Accuracy 10 95 RH 5 Humidity Range Set Point 35 70 Auxillary Relay Capacity 5 Amps 24VAC Temp Range Accuracy 30 90 F 1 32 C 2 Size 4 95 L x 1 06 W x 4 19 H 12 6 cm L x 2 7 cm W x 10 6 cm H Major Operations Digital control of Relative Humidity Digital Set Point Fan Filter Operation Programmable Ventilation Timer Large easy to read backlit L...

Page 12: ...g it gently against the unit until the snap button secures the door Notes Impeller Fan Oiling The impeller fan motor is factory lubricated for many years of normal operation and no further oiling is required Optional Fresh Air Intake Check and clean the screen on the outdoor fresh air intake port seasonally The screen may become plugged during seasons when there are many particles in the outdoor a...

Page 13: ... N O COM COIL BLK 13 FANRELAY GRN 1 BLK 6 BLK 11 DEFROST SWITCH COMPRESSOR RELAY DEHUMIDISTAT R FAN BLU 9 GRN 15 BRN 14 BLK 13 FAN CAPACITOR REDCIRCUITIS24VACCONTROLCIRCUIT 4038488 GRN 25 RED 20 RED 8 RED 8 BLK 28 RED 20 BLK 28 BLK 10 BLK 11 BLK 5 BLU 19 YEL 33 YEL 17 RED 23 YEL 16 RED 23 RED 24 CIRCUIT BREAKER 24V RED 21 COM DMPR DEHU BLU 18 FAN RED 24 RED 21 BLK 10 BLK 12 BLK 12 ...

Page 14: ...g up its heat to the supply air being discharged from the unit The refrigerant liquid then passes through a strainer and Warranty A consumer warranty certification is included at the end of the manual Please read it before any repair is initiated If a warranty repair is required call the install ing contractor or the factory at 1 855 239 2665 for warranty claim authorization and technical assistan...

Page 15: ...rotation 3 Defective fan 4 Defective fan relay Low dehumidification capacity evaporator is frosted continuously Dehumidification is being called for 1 Defrost thermostat loose or defective 2 Low refrigerant charge 3 Dirty air filter s or air flow restricted 4 Excessively restrictive ducting connected to unit No ventilation Ventilation is being called for 1 Loose connection in ventilation control c...

Page 16: ...ndards If the dehumidifier fails to ventilate as expected check that the time on the timer is correct Also check the programs on the timer to be sure that the timer is calling for ventila tion at the correct times i WARNING ELECTRICAL SHOCK HAZARD Electrical power must be present to perform some tests These tests should be performed by a qualified service person Unit Test to Determine Problem 1 De...

Page 17: ...ircuit i CAUTION DO NOT connect high voltage to the damper motor or damage to the motor will result i CAUTION DO NOT force the blade of the damper by hand or damage to the damper motor may result The damper opens in one direction only The damper rotates very slowly allow sufficient time for the damper to cycle The damper opens in one direction only It rotates very slowly be sure to allow sufficien...

Page 18: ...et at the four locations Step 3 Hand tighten the hose adaptor to get the threads started Turn clockwise Step 4 Use adjustable pliers to finish tightening Fully seat the drain adaptor so that no leaks occur Step 5 Install a sufficiently long drain hose to connect the drain adaptor of the dehumidifier to the condensate pump reservoir using field supplied fittings Step 6 Attach a drain hose to the co...

Page 19: ...tomer s or Customer s employees agents invitees or a third party s misuse improper installation improper design of any system in which the Product is included abuse lack of normal care failure to follow written instructions tampering improper repair or freezing corrosion acts of nature or other causes not arising out of defects in workmanship or material If a Product or Component is replaced while...

Page 20: ...eserves the right to discontinue or change at any time specifications or designs without notice or without incurring obligations 2017 Goodman Manufacturing Company L P Houston Texas Printed in the USA WWW CLEANCOMFORT COM TECHNICAL SUPPORT 1 833 40 CLEAN 25326 Notes ...

Reviews: