WWW.CLEANCOMFORT.COM
12
MAINTENANCE
IO-DV070
IO-DV070
Maintenance
For Homeowner - Routine Maintenance
Part No.
Description
DVP-4034731 9"x11"x1" MERV 11 filter for
DV070 dehumidifier
High-Efficiency Air Filter
The Clean Comfort Ventilating Dehumidifiers are
equipped with a MERV 11 media filter. This filter should
be checked every three months and changed every 6-12
months. Operating the unit with a dirty filter will reduce
dehumidifier capacity and efficiency and may cause the
compressor to cycle OFF and ON unnecessarily on the
defrost control.
Figure 10:
Remove the filter by gently pulling
straight out of the unit. Insert new filter in
the same manner, pushing it gently straight
into the unit.
Figure 11:
Replace filter door by inserting the
bottom tab into the slot, aligning the door
and pushing it gently against the unit until the
snap button secures the door.
Notes:
Impeller Fan Oiling
The impeller fan motor is factory lubricated for many
years of normal operation, and no further oiling is
required.
Optional Fresh Air Intake
Check and clean the screen on the outdoor fresh air
intake port seasonally. The screen may become plugged
during seasons when there are many particles in the
outdoor air.
i
WARNING!
DO NOT operate the DV070 dehumidifier without
the MERV 11 filter or with a filter of lower
performance rating than MERV 11. The heat
exchange coils inside the unit could become clogged
and require disassembly to clean. Non-compliance
with filter maintenance guidelines (provided above)
invalidates the product warranty.
To replace the filter, remove the filter door from one of
the sides of the DV070 Dehumidifier by pushing the snap
button in and gently pulling to door away from the body
of the unit, then pulling up to disengage the door flange
from the slot, removing the door.