Cleaning and Maintenance 

You can ensure many years of trouble free operation of your 

Clean Air Optima CA-604

 humidifier 

by following a few simple maintenance procedures. If your water is hard, containing high 

concentrations of calcium and other minerals, then over a period of time white dust will start to 

deposit on the various surfaces in the room. A white, film-like substance will also start to develop 

in the water basin, on the transducer and on the inner surface of the water tank. This white film 

will impede the proper function of the transducer and the operation of the machine. 

 

 

We recommend the following 

 

1.

 

If your water is very hard, we recommend that you boil it first, allow it to cool completely 

before use in the humidifier. The boiling will reduce the mineral concentration in the water. 

The other option is to use distilled water if your mineral level is still too high. 

2.

 

If you are using the machine on a daily basis, clean the transducer, water tank and basin 

once a week. 

3.

 

When the water tank needs a refill, empty the remaining water from the tank and fill it with 

fresh water. 

4.

 

Clean the whole machine and make sure to keep all the parts completely dry when the 

machine is not in use. 

 
 

How to clean the transducer 

 

1.

 

Place 5-10 drops of vinegar on the surface of the transducer and wait for 2-5 minutes. 

2.

 

Using a small brush, cotton swab or tooth brush, gently clean the mineral film from the 

surface of the transducer. 

3.

 

Rinse the transducer with clean water. 

4.

 

Never use sharp or solid objects for cleaning the transduce 

 
 
 
 
 
 
 
 

 

How to clean the water basin 

 

1.

 

Clean the water basin with a soft damp cloth. If there is excess film on the surfaces, then 

soak the cloth with vinegar and repeat the process. 

2.

 

If there is a film in any of the depressions along the basin, drop a bit of vinegar into 

depression and clean it out with a brush. 

3.

 

Rinse the basin with clean water.

 

 

 

 

 

 

 

Do not use additives 

Water additives (e.g. essential oils, fragrances, water conditioners etc.) must NOT be used! Even a small 

amount can cause damage to the tank material. The material is not suitable for the use of such additives. One 
drop is enough to damage the tank and render the appliance unusable. Appliances that are damaged by such 

additives will not be covered by the manufacturer’s warranty. 

Summary of Contents for CA-604

Page 1: ...1 Ultrasonic Humidifier with Ionizer CA 604 Instruction Manual ...

Page 2: ... not operate the unit without water in the basin Do not insert foreign objects into the device Do not touch the transducer or the lower water basin when the unit is operating Do not scratch the transducer Do not touch the mist output when producing warm mist Do not submerge this device in water Water or cleaning liquids may only be used on parts to be cleaned according to the cleaning and maintena...

Page 3: ...ur logo Major components of CA 604 1 Output Jets 2 Top Water Tank Handle 3 Front Panel 4 Digital Display and Control Buttons 5 6L 1 6 gal Water Tank 6 Water Tank Opening for Filling 7 Permanent Reusable White Dust Anti Microbial Filter 8 Water Tank Lid and Seal 9 Lower Body and Basin 10 Power Cord 11 Transducer 12 Power Light Power Switches the humidifier on off Ion Switches negative ions on off H...

Page 4: ...alue of time remaining in timer 20 Mist volume indicator low medium and high The Clean Air Optima CA 604 is equipped with a Permanent Reusable White Dust Anti Microbial Filter It consists of an inner cylinder an outer cover and a number of small plastic and ceramic balls The plastic balls are embedded with nano silver an anti microbial agent designed to purify the water and destroy microbes such a...

Page 5: ... the faucet for filling grasping it from the handle under the water tank Fill the tank with tap water or other clean water source with water temperature under 40ºC re insert the lid and filter Flip the water tank once again until it is on the right side up Ensure that the basin is clean and then carefully place the water tank back on the lower body Wait a few seconds until the water tank lid start...

Page 6: ...e automatic mode very easily by pressing the humidity button until you reach 90 RH Press the button one more time and you will now be in manual mode You will know that you are in manual mode because the blinking SETUP icon disappears Pressing the Ion Button will activate the negative ion generator and start sending healthy negative ions into the air It will be represented by the tree icon 19 displ...

Page 7: ...ter is too dirty or water was kept too Clean the water tank and refill long in the tank with clean water Abnormal noise Vibration in the water tank because Fill the water tank the water level is too low Machine is on an unstable surface Move the unit to a stable flat surface Spray mist is coming out of the There are gaps between the housing Remove the jet nozzle from the area around the jets aroun...

Page 8: ...pty the remaining water from the tank and fill it with fresh water 4 Clean the whole machine and make sure to keep all the parts completely dry when the machine is not in use How to clean the transducer 1 Place 5 10 drops of vinegar on the surface of the transducer and wait for 2 5 minutes 2 Using a small brush cotton swab or tooth brush gently clean the mineral film from the surface of the transd...

Page 9: ...ially in the winter months it can become unpleasant and even unhealthy leading to increased levels of static electricity dry skin cracked lips and even noise bleeds Optimal humidity is between 45 to 55 relative humidity During the winter months though relative humidity in the average home can drop to below 20 Low humidity can lead to a variety of conditions that cause ill health Dust particles bac...

Page 10: ...tank Large capacity water tank 6L 1 6 gallon easy refills with normal tap water Runs up to 7 nights or 60 ours without refilling low setting Save money No wicks or filters to replace Low power consumption Applicable for small and larger rooms up to 590 ft 55m 140m Benefits of proper humidification reduces discomfort tiredness sickness reduces susceptibility to colds reduces chapped lips dry red ey...

Page 11: ...ded that the malfunction or damage to the device and or parts occurred under normal operating conditions What is covered All parts defective in material and workmanship For how long Two years from purchase date What we will do Repair or replace any defective parts Exclusions Regular replacement parts such as filter cartridges Other Conditions The provisions of this warranty are in lieu of any othe...

Reviews: