Clean Air CA-603 Instruction Manual Download Page 6

 

 

 

 

 
 
The 

Clean Air Optima CA-603

 is equipped with a 

Permanent Reusable White Dust & Anti-

Microbial Filter

. It consists of an inner cylinder, an outer cover and a number of small plastic and 

ceramic balls. The plastic balls are embedded with nano-silver, an anti-microbial agent designed to 
purify the water and destroy microbes such as bacteria and mould. The ceramic balls function to 
soften the water by adhering to minerals that cause white dust. They also serve to remove any 
unpleasant odour from the water. The filter requires cleaning about once a month or 1,000 hours of 
use. See the 

Maintenance section

 of more information. 

OPERATING INSTRUCTIONS 

 

 

 
 
 
 

Operating Instructions 

 

Before getting started, please remove the 

Clean Air Optima CA-603

 from its box and allow it to 

become accustomed to the room temperature for at least 30 minutes especially if the machine is 
cold from the outside air. The CA-603 is designed to operate at temperatures between 5 -40 ºC 
and relative humidity of less than 80%.  
 
 
To get started, first remove the nozzele than grasp the water tank by the handle at the top and lift 
from the base. Next, flip the tank over and unscrew and remove the water tank lid and filter.

 

 
 
Then place the water tank under the faucet for filling. Fill the tank with tap water (or other clean 
water source with water temperature under 40ºC), re-insert the lid and filter. Flip the water tank 
once again until it is on the right side up. Ensure that the basin is clean and then carefully place 
the water tank back on the lower body. 
 
Wait a few seconds until the water tank lid starts to release water into the basin. You will hear a 
bubbling sound as the air enters the water tank. Plug the power cord into the electrical outlet 
(NEVER SWITCH ON THE HUMIDIFIER WITHOUT WATER IN THE BASIN). If the humidifier is 
switched off, the power icon should now be red and the values for temperature and humidity will 
now be displayed. 
 
 
 
 
 
 
 
 
 

Summary of Contents for CA-603

Page 1: ...1 Ultrasonic Humidifier with Ionizer and Aromatherapy CA 603 Instruction Manual ...

Page 2: ...cratch the transducer Do not touch the mist output when producing warm mist Do not submerge this device in water Water or cleaning liquids may only be used on parts to be cleaned according to the cleaning and maintenance instructions Only use lime scale remover or vinegar to clean mineral deposits from the basin or transducer Do not use any harsh detergents that may damage the unit The use of othe...

Page 3: ...zzle 2 handle 3 water tank 4 water inlet 5 filter cartridge 6 tank cover 7 cord plug 8 water level sensor 9 transducer 10 fan Ionizer 11 base waterbassin 12 led light indicator on 13 display with touch buttons 14 aroma box ...

Page 4: ...battery area located at the bottom edge of the unit just below our logo The LCD display shows the numeric values for temperature and relative humidity and the length of time remaining on the timer It also displays the icons used to indicate other humidifier functions LCD Display On Off Switches the humidifier on off Ion Switches negative ions on off Max Min Sets misting spray level to low medium o...

Page 5: ...ording to the newest nebulisation technology based on ultrasound in order to atomise essential oils and water into microscopically small drops Thanks to this technology the components and the water can unfold their beneficial potential for humans Filling and refilling with essential oils Eucalyptus 10ml Vanilla 10ml Lavender 10ml Jasmine 10ml Lemon 10ml Rosemary 10ml To order www cleanairoptima co...

Page 6: ...chine is cold from the outside air The CA 603 is designed to operate at temperatures between 5 40 ºC and relative humidity of less than 80 To get started first remove the nozzele than grasp the water tank by the handle at the top and lift from the base Next flip the tank over and unscrew and remove the water tank lid and filter Then place the water tank under the faucet for filling Fill the tank w...

Page 7: ...y level will be set Wait another 5 seconds and the numeric value on the LCD display will switch to the current humidity level as measured by the built in Hygrostat When the humidity level in the room reaches the set humidity level the machine will go into automatic sleep state and stop producing mist When the room s actual humidity level drops below your set humidity level then the machine will st...

Page 8: ...o dirty or water was kept too Clean the water tank and refill long in the tank with clean water Abnormal noise Vibration in the water tank because Fill the water tank the water level is too low Machine is on an unstable surface Move the unit to a stable flat surface Spray mist is coming out of the There are gaps between the housing Remove the jet nozzle from the area around nozzele jet around jet ...

Page 9: ...he whole machine and make sure to keep all the parts completely dry when the machine is not in use How to clean the transducer 1 Place 5 10 drops of vinegar on the surface of the transducer and wait for 2 5 minutes 2 Using a small brush cotton swab or tooth brush gently clean the mineral film from the surface of the transducer 3 Rinse the transducer with clean water 4 Never use sharp or solid obje...

Page 10: ...midity in the average home can drop to below 20 Low humidity can lead to a variety of conditions that cause ill health Dust particles bacteria viruses dust mite feces that are normally trapped by the moist nasal membrane lining in the nose can more easily get into the lungs when the air is dryer and thus reduce the body s natural defence mechanism These invaders overload the immune system and irri...

Page 11: ...er indicator notifies when to refill the tank Large capacity water tank 5L 1 32 US gallons easy refills with normal tap water Runs up to 5 nights or 50 hours without refilling low setting Save money No wicks or filters to replace Low power consumption Applicable for small and larger rooms up to 480 ft 45m 100m Benefits of proper humidification reduces discomfort tiredness sickness reduces suscepti...

Page 12: ...unction or damage to the device and or parts occurred under normal operating conditions What is covered All parts defective in material and workmanship For how long Two years from purchase date What we will do Repair or replace any defective parts Exclusions Regular replacement parts such as filter cartridge Other Conditions The provisions of this warranty are in lieu of any other written warranty...

Reviews: