Clean Air CA-603 Instruction Manual Download Page 2

 

 

 

 

 
 
Thank you for purchasing the innovative 

Clean Air Optima CA-603

 Digital Cool Mist ultrasonic 

humidifier with Ionizer and Aromatherapy. 
We wish you many years of healthy indoor air with this efficient and effective product. 
 
Ensure that all safety precautions are followed when using this electrical appliance for the proper 
operation of the device. These instructions describe the safety precautions to be observed during 
operation. They are designed to prevent injuries or damage to this device. 
 

Safety Precautions 

 

The inner ultrasonic transducer is highly sensitive. Do not touch it with bare fingers or 

scrape it with metal tools, or it will reduce mist output. When cleaning this area please use 
a small cleaning brush, cotton swab or tooth brush. Do not use hot water as it may damage 
the misting parts. 

 

Use proper voltage - AC 110~120V 60Hz in Canada/USA; AC 220~240V 50Hz in Europe. 

Use of improper voltage may cause fire hazard or electric shock. 

 

To prevent electric shock, do not dismantle, repair or modify this product. Maintenance and 

cleaning should be followed exactly as instructed in this manual. In the event of a 
malfunction, please contact an authorized 

Clean Air Optima

 maintenance center. 

 

Do not use in areas where flammable or explosive materials are stored. 

 

Do not place this device in direct sunlight or near objects that generate high temperature 

heat. The heat may cause deformation or warping of the outer casing. 

 

Do not use the humidifier in a room that already has humidity levels above 50% relative 

humidity. Excessive humidity in the room gives rise to condensation on cold surfaces such 
as walls or windows. 

 

Do not operate the unit without water in the basin. 

 

Do not insert foreign objects into the device. Do not touch the transducer or the lower 

water basin when the unit is operating. Do not scratch the transducer. Do not touch the 
mist output when producing warm mist. 

 

Do not submerge this device in water. Water or cleaning liquids may only be used on parts 

to be cleaned according to the cleaning and maintenance instructions. 

 

Only use lime scale remover or vinegar to clean mineral deposits from the basin or 

transducer. Do not use any harsh detergents that may damage the unit. 

 

The use of other essential oils not made for this air humidifier or other additives (for 

example pure essential oils, fragrances, water purification products) can damage the air 
humidifier and must NOT be used! Even a small quantity can damage the plastic and cause 
cracks. The material is not made for the use of additives. One drop is enough to damage 
the water tank/ basin and disable the device. Devices that are damaged through additives 
are excluded from the guarantee.   

 

If you smell an abnormal odour, please turn off and unplug the unit and call 

Clean Air 

Optima

 technical support. 

 

Clean and dry the device before storage (including the removal of all water from the inside 

of the device). Store the machine in a cool and dry place outside the reach of children. 

 

Do not use fabrics or other materials to cover this device. Obstructed air inlets and outlets 

will result in improper operation of this unit and may result in fire or other damage. 

 

To prevent interference and damage to other electronic devices, this machine should be 

placed at least 1 meter away from a computer, television, radio or other electronic 
equipment. 

 

The ultrasonic humidifier should be cleaned regularly for proper operation and long life. See 

cleaning instructions.  

 

For safety reasons and to prevent fire or electric shock, unplug the power cord from the 

electric outlet socket whenever you: 

 
 

-

 

Do not use the device for a long period of time. 

-

 

Remove the tank, clean or service the machine or the permanent filter. 

-

 

Move or transport the device. 

 

If the power cord is damaged, then it must be replaced by an authorized service person to prevent 
electric shock or fire. 

 

 

Summary of Contents for CA-603

Page 1: ...1 Ultrasonic Humidifier with Ionizer and Aromatherapy CA 603 Instruction Manual ...

Page 2: ...cratch the transducer Do not touch the mist output when producing warm mist Do not submerge this device in water Water or cleaning liquids may only be used on parts to be cleaned according to the cleaning and maintenance instructions Only use lime scale remover or vinegar to clean mineral deposits from the basin or transducer Do not use any harsh detergents that may damage the unit The use of othe...

Page 3: ...zzle 2 handle 3 water tank 4 water inlet 5 filter cartridge 6 tank cover 7 cord plug 8 water level sensor 9 transducer 10 fan Ionizer 11 base waterbassin 12 led light indicator on 13 display with touch buttons 14 aroma box ...

Page 4: ...battery area located at the bottom edge of the unit just below our logo The LCD display shows the numeric values for temperature and relative humidity and the length of time remaining on the timer It also displays the icons used to indicate other humidifier functions LCD Display On Off Switches the humidifier on off Ion Switches negative ions on off Max Min Sets misting spray level to low medium o...

Page 5: ...ording to the newest nebulisation technology based on ultrasound in order to atomise essential oils and water into microscopically small drops Thanks to this technology the components and the water can unfold their beneficial potential for humans Filling and refilling with essential oils Eucalyptus 10ml Vanilla 10ml Lavender 10ml Jasmine 10ml Lemon 10ml Rosemary 10ml To order www cleanairoptima co...

Page 6: ...chine is cold from the outside air The CA 603 is designed to operate at temperatures between 5 40 ºC and relative humidity of less than 80 To get started first remove the nozzele than grasp the water tank by the handle at the top and lift from the base Next flip the tank over and unscrew and remove the water tank lid and filter Then place the water tank under the faucet for filling Fill the tank w...

Page 7: ...y level will be set Wait another 5 seconds and the numeric value on the LCD display will switch to the current humidity level as measured by the built in Hygrostat When the humidity level in the room reaches the set humidity level the machine will go into automatic sleep state and stop producing mist When the room s actual humidity level drops below your set humidity level then the machine will st...

Page 8: ...o dirty or water was kept too Clean the water tank and refill long in the tank with clean water Abnormal noise Vibration in the water tank because Fill the water tank the water level is too low Machine is on an unstable surface Move the unit to a stable flat surface Spray mist is coming out of the There are gaps between the housing Remove the jet nozzle from the area around nozzele jet around jet ...

Page 9: ...he whole machine and make sure to keep all the parts completely dry when the machine is not in use How to clean the transducer 1 Place 5 10 drops of vinegar on the surface of the transducer and wait for 2 5 minutes 2 Using a small brush cotton swab or tooth brush gently clean the mineral film from the surface of the transducer 3 Rinse the transducer with clean water 4 Never use sharp or solid obje...

Page 10: ...midity in the average home can drop to below 20 Low humidity can lead to a variety of conditions that cause ill health Dust particles bacteria viruses dust mite feces that are normally trapped by the moist nasal membrane lining in the nose can more easily get into the lungs when the air is dryer and thus reduce the body s natural defence mechanism These invaders overload the immune system and irri...

Page 11: ...er indicator notifies when to refill the tank Large capacity water tank 5L 1 32 US gallons easy refills with normal tap water Runs up to 5 nights or 50 hours without refilling low setting Save money No wicks or filters to replace Low power consumption Applicable for small and larger rooms up to 480 ft 45m 100m Benefits of proper humidification reduces discomfort tiredness sickness reduces suscepti...

Page 12: ...unction or damage to the device and or parts occurred under normal operating conditions What is covered All parts defective in material and workmanship For how long Two years from purchase date What we will do Repair or replace any defective parts Exclusions Regular replacement parts such as filter cartridge Other Conditions The provisions of this warranty are in lieu of any other written warranty...

Reviews: