background image

 

 

The following is not considered faulty operation: 
 

 

If your water is very hard (containing abnormally high levels of minerals) the humidifier 
may produce white dust. This is not a malfunction. The solution would be to clean the 
filter more often or use softer water. 

 

If you stand very close to the humidifier, you will hear the gurgling sound of water. This 
is normal. 

 

The machine operates very quietly but it is not completely silent. Noise levels less than 
25 db is considered normal. 

WARNING! 
If the above recommended solutions do not work, please contact 

Clean Air Optima

 technical 

support at the telephone number for your region. Do not attempt to disassemble, repair 
and reassemble the machine as it may void the warranty

TROUBLESHOOTING 

 
Cleaning and Maintenance 

You can ensure many years of trouble free operation of your 

Clean Air Optima CA-601

 humidifier 

by following a few simple maintenance procedures. If your water is hard, containing high 
concentrations of calcium and other minerals, then over a period of time white dust will start to 
deposit on the various surfaces in the room. A white, film-like substance will also start to develop 
in the water basin, on the transducer and on the inner surface of the water tank. This white film 
will impede the proper function of the transducer and the operation of the machine. 

 
 
We recommend the following 
 

1.

 

If your water is very hard, we recommend that you boil it first, allow it to cool completely 

before use in the humidifier. The boiling will reduce the mineral concentration in the water. 
The other option is to use distilled water if your mineral level is still too high. 

2.

 

If you are using the machine on a daily basis, clean the transducer, water tank and basin 

once a week. 

3.

 

When the water tank needs a refill, empty the remaining water from the tank and fill it with 

fresh water. 

4.

 

Clean the whole machine and make sure to keep all the parts completely dry when the 

machine is not in use. 
 
 

How to clean the transducer 
 

1.

 

Place 5-10 drops of vinegar on the surface of the transducer and wait for 2-5 minutes. 

2.

 

Using a small brush, cotton swab or tooth brush, gently clean the mineral film from the 

surface of the transducer. 

3.

 

Rinse the transducer with clean water. 

4.

 

Never use sharp or solid objects for cleaning the transduce 

 

How to clean the water basin 
 

1.

 

Clean the water basin with a soft damp cloth. If there is excess film on the surfaces, then 

soak the cloth with vinegar and repeat the process. 

2.

 

If there is a film in any of the depressions along the basin, drop a bit of vinegar into 

depression and clean it out with a brush. 

3.

 

Rinse the basin with clean water.

 

 

 

 

 

Summary of Contents for CA-601

Page 1: ...1 Ultrasonic Humidifier with Ionizer CA 601 Instruction Manual ...

Page 2: ...the unit without water in the basin Do not insert foreign objects into the device Do not touch the transducer or the lower water basin when the unit is operating Do not scratch the transducer Do not touch the mist output when producing warm mist Do not submerge this device in water Water or cleaning liquids may only be used on parts to be cleaned according to the cleaning and maintenance instructi...

Page 3: ...3 Diagram humidifier CA 601 ...

Page 4: ... clean water source with water temperature under 40ºC re insert the lid and filter Flip the water tank once again until it is on the right side up Ensure that the basin is clean and then carefully place the water tank back on the lower body Wait a few seconds until the water tank lid starts to release water into the basin You will hear a bubbling sound as the air enters the water tank Plug the pow...

Page 5: ...mist No water in water tank Fill water tank with water The mist has a strange odour A new machine Remove the water tank unscrew the lid and let it air out in a cool area for 12 hours It either has dirty water or the water Clean the water tank and refill has been stagnant too long with clean water Power light is on but the Too much water in the water basin Remove the water tank Take a machine doesn...

Page 6: ...f the water tank This white film will impede the proper function of the transducer and the operation of the machine We recommend the following 1 If your water is very hard we recommend that you boil it first allow it to cool completely before use in the humidifier The boiling will reduce the mineral concentration in the water The other option is to use distilled water if your mineral level is stil...

Page 7: ... humidity can lead to a variety of conditions that cause ill health Dust particles bacteria viruses dust mite feces that are normally trapped by the moist nasal membrane lining in the nose can more easily get into the lungs when the air is dryer and thus reduce the body s natural defence mechanism These invaders overload the immune system and irritate the mucous membranes resulting in more coughin...

Page 8: ...s susceptibility to colds reduces chapped lips dry red eyes and dry itchy skin helps to feel and sleep better can help you recover sooner from a cold reduces damage to wooden objects reduces the negative effect of dry air on musical instruments reduces static electricity charge helps to keep your voice tuned Benefits of ionisation Ionised air strengthens our defence systems and our vitality and io...

Page 9: ... What is covered All parts defective in material and workmanship For how long Two years from purchase date What we will do Repair or replace any defective parts Exclusions Regular replacement parts such as filter cartridges Other Conditions The provisions of this warranty are in lieu of any other written warranty whether express or implied written or oral including any warranty of merchantability ...

Reviews: