Installation, Operation & Maintenance Guide
FC-400 Series
6
1-888-MY-AIR11 CAG-06-21-003 AtmosAir.com
Electrical Installation
■
AtmosAir FC-400 series systems require an average of 4.5 watts per unit.
■
Follow proper electrical procedures, guidelines, and codes for providing power supplies to the systems.
Including
requirements for conduit, sufficient ampacity, phase balancing, etc. Electrical installation should be performed by a qualified
electrician.
■
Field-install a power plug outlet or power receptacle within 1.83 meters (6’) of the unit(s).
■ Each FC-400 series unit is shipped with an 2.44 meters (8’) power cord with a field install pair of wire hot/neutral connector on
one end and a quick-disconnect plug on the other end. The FC-400FM has a polarized quick-disconnect on the unit. Each unit is
shipped with two wiring options per country-specific requirements:
1.
Two-conductor, field wire connection (No Ground)
2.
NEMA 5-15 two-prong plug adapter
Caution!
A non-functioning LED light may improperly indicate that the system is not functioning. Be sure to disconnect from the main power before performing
maintenance or troubleshooting the system.
!!!WARNING!!!
THE SECONDARY VOLTAGE TO THE IONIZATION TUBE CAN BE AS HIGH AS
3000 VOLTS AC. DO NOT CONNECT TO POWER BEFORE THE INSTALLATION IS COMPLETE
AND ALL PERSONNEL ARE AWARE OF IMMINENT OPERATION. ALWAYS DISCONNECT
POWER TO THE UNIT BEFORE HANDLING ANY OF THE COMPONENTS.