CLEAN AIR GROUP, INC. – PRODUCT WARRANTY 

Clean Air Group, Inc. d/b/a AtmosAir Solutions (“Clean Air Group”) warrants to the original purchaser of this product (“Customer”), 

that should it prove to be defective by reason of improper materials or workmanship, for 

twenty-four (24) months 

from the date 

of installation, or 

twenty-seven (27) months 

from the date of Clean Air Group’s delivery of the product, whichever occurs first, 

Clean Air Group shall repair or replace the product without charge to the Customer. Proof of malfunction and return of the non-

working product must be presented by the Customer if submitting a warranty claim. This warranty is invalid if the factory applied 

serial number has been altered or removed from the product. This warranty does not cover damage due to acts of God, misuse, 

abuse, negligence, or modification of or to any part of the product. This warranty does not cover damage due to improper 

installation, operation or maintenance, connection to improper voltage or electrical supply, or repair by anyone other than an 

authorized Clean Air Group service provider. To obtain warranty service the Customer must: (1) provide proof of purchase in 

the form of a Bill of Sale or receipted invoice, with evidence that the product is within the warranty period; (2) request a Return 

Merchandise Authorization (“RMA”) from Clean Air Group prior to shipping; and (3) ship the product with the RMA to Clean Air 

Group, freight prepaid, in either its original packaging or packaging affording an equal degree of protection. The product should 

be delivered to 

AtmosAir, 2115 East Cedar Street, Suite 6, Tempe, AZ 85281

. All transportation charges and shipping expenses 

are the Customer’s responsibility. Clean Air Group will return the product by the same method it receives the product. A product 

returned for repair after the warranty period, or that shows damage outside of the warranty coverage described herein, shall be 

repaired for a reasonable charge as determined by Clean Air Group. The Customer will be advised of the cost of repair or 

replacement before Clean Air Group proceeds.  

THE OBLIGATIONS OF CLEAN AIR GROUP HERIN ARE EXPRESSLY GRANTED IN LIEU OF ALL WARRANTS, WHETHER 

EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE. ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND 

FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO THE TERM OF THE EXPRESS WARRANTY GRANTED HEREIN. 

Some states do not allow limitations on how long an implied warranty lasts, so the foregoing limitation or exclusion may not apply 

to you.  

With the exception of damages resulting from Clean Air Group’s failure to comply with any obligation under federal or state 

warranty laws, Clean Air Group SHALL NOT BE LIABLE TO THE CUSTOMER OR ANY OTHER PERSON OR THIRD PARTY 

FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO CONSEQUENTIAL, SPECIAL, INDIRECT, INCIDENTAL AND 

PUNITIVE DAMAGES AND/OR DAMAGES BY REASON OF INJURY TO ANY PERSON DUE TO ANY DEFECT OR 

MALFUNCTION OF THE PRODUCT OR ANY PART OR PARTS THEREOF OR FOR ANY OTHER REASON. This warranty 

gives you specific legal rights and you may have rights which vary from state to state.  If your product is defective please contact 

Clean Air Group or the dealer where you purchased the unit. 

Disclaimer: 

The air purification technology provided by AtmosAir is intended to improve air quality.  It is not intended to  replace 

reasonable precautions to prevent the transmission of airborne contaminants. Customer, its employees, invitees and all persons 

having access to the serviced premises should comply with all applicable public health laws and guidelines issued by federal, 

state and local governments and health authorities such as the Centers for Disease Control and Prevention (CDC). These 

precautions include but are not limited to wearing face masks, social distancing, hand hygiene and appropriate sanitizing and 

disinfecting. Clean Air Group does not assert that its products can protect people from viruses, bacteria or other airborne 

contaminants, expressly excludes liability for loss or damage arising from any such claims, and does not assume any liability for 

the consequences arising out of the application, use or misuse of its products, including any injury or damage to any person or 

damage to any property as a matter of product liability, negligence, contract or otherwise. 

Manufacturer, 

Anthony M. Abate 

Chief Technology Officer 

Clean Air Group, Inc. 

08 

PRODUCT WARRANTY

Summary of Contents for AtmosAir FC-400 Series

Page 1: ...to its pure natural state where no pollution or contaminants exist while reducing energy use and emissions in the process AtmosAir com CAG 06 21 003 IMPORTANT Save this Document for Future Reference Warranty Information FC 400 Series Installation Operation and Maintenance Guide ...

Page 2: ...let before beginning the installation Follow each installation or repair step exactly as shown and explained in this guide Observe all local state national and international electrical codes Pay close attention to all warnings and caution notices given in this guide CAUTION Do not touch while in operation shut off electricity before servicing This equipment should be inspected frequently and colle...

Page 3: ...PRODUCT OVERVIEW 4 FC 400 Diagram 4 02 INSTALLATION 5 Mechanical Installation 5 Electrical Installation 6 03 FIELD WIRING DIAGRAMS 7 Diagram 1 8 Diagram 2 9 Diagram 3 10 Diagram 4 11 Diagram 5 12 04 OPERATION 13 05 MAINTENANCE RECOMMENDATIONS 13 06 TROUBLESHOOTING 14 07 EXPLANATION OF TECHNOLOGY 15 08 PRODUCT WARRANTY 16 ...

Page 4: ...the space and severity of the pollution and odors The AtmosAir FC 400 series equipment is designed for minimal maintenance The FC 400 series has two components that require inspection and maintenance 1 AtmosAir FC 400 series base unit components fuse 2 Ionization tube There are no user serviceable components inside Because there are no moving parts little maintenance is required and the systems ha...

Page 5: ...ently pull the conductor strap back to allow the tube to turn freely screw the end screw of the tube into the tube holder hand tight Ensure that the tube is FULLY SEATED 3 Once the tube is secure return the conductor strap to its normal position and ensure solid flat and continuous contact is made with the tube s outer mesh See page 8 WARNING The secondary voltage to the ionization tubes can be as...

Page 6: ...d with a field install pair of wire hot neutral connector on one end and a quick disconnect plug on the other end The FC 400FM has a polarized quick disconnect on the unit Each unit is shipped with two wiring options per country specific requirements 1 Two conductor field wire connection No Ground 2 NEMA 5 15 two prong plug adapter Caution A non functioning LED light may improperly indicate that t...

Page 7: ...DIAGRAM FC 400 SERIES TO AFS 262 AIRSWITCH SHEET 1 OF 1 UNLESS OTHERWISE SPECIFIED SCALE 1 3 REV C DWG NO A SIZE TITLE NAME DATE COMMENTS FIELD WIRING DIAGRAM FOR CONNECTING FC 400 SERIES TO AFS 262 AIR SWITCH TO LINE VOLTAGE Q A Rev C SB 3 12 21 ENG APPR TA 2 21 19 2 21 19 DRAWN HRG 2 21 19 FINISH MATERIAL INTERPRET GEOMETRIC TOLERANCING PER DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 010 ANGU...

Page 8: ...2 AIRSWITCH PLUG SHEET 1 OF 1 UNLESS OTHERWISE SPECIFIED SCALE 1 3 REV A DWG NO A SIZE TITLE NAME DATE COMMENTS FIELD WIRING DIAGRAM FOR CONNECTING FC 400 SERIES TO AFS 262 AIR SWITCH TO PLUG Q A ENG APPR HG 3 12 21 DRAWN SB 3 12 21 FINISH MATERIAL INTERPRET GEOMETRIC TOLERANCING PER DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 010 ANGULAR MACH BEND TWO PLACE DECIMAL 010 THREE PLACE DECIMAL APPL...

Page 9: ...SIZE TITLE ATMOSAIR SOLUTIONS NAME DATE PRODUCTION APPR ENG APPR CHECKED DRAWN SB FINISH MATERIAL INTERPRET GEOMETRIC TOLERANCING PER DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL xxx ANGULAR MACH xxx BEND TWO PLACE DECIMAL xxx THREE PLACE DECIMAL APPLICATION USED ON NEXT ASSY PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF ATMOSAIR SOLUTIONS ANY REP...

Page 10: ...ALE 1 4 WEIGHT REV A Created 3 26 2021 A SIZE TITLE ATMOSAIR SOLUTIONS NAME DATE PRODUCTION APPR ENG APPR CHECKED DRAWN FINISH MATERIAL INTERPRET GEOMETRIC TOLERANCING PER DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL xxx ANGULAR MACH xxx BEND TWO PLACE DECIMAL xxx THREE PLACE DECIMAL APPLICATION USED ON NEXT ASSY PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE ...

Page 11: ...RTICAL FAN COIL FC 400 MOUNTING SHEET 1 OF 1 3 25 21 3 25 21 HG UNLESS OTHERWISE SPECIFIED SCALE 1 4 WEIGHT REV A Created 3 25 2021 A SIZE TITLE ATMOSAIR SOLUTIONS NAME DATE PRODUCTION APPR ENG APPR CHECKED DRAWN SB FINISH MATERIAL INTERPRET GEOMETRIC TOLERANCING PER DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL xxx ANGULAR MACH xxx BEND TWO PLACE DECIMAL xxx THREE PLACE DECIMAL APPLICATION USED ...

Page 12: ...low to high clockwise Typically it is suggested to start at a baseline of 50 ionization Twenty four hours later re evaluate your air quality and adjust accordingly 2 Plug the power cord on the FC 400 ionization system into the plug receptacle 3 Once the FC 400 system is plugged in the system will be on Check that the blue embedded LED light is lit The LED is programmed to indicate that the system ...

Page 13: ...e tube as shown below The next step is to determine the cause of the failure or blown fuse Typically failures are caused by arcing between the inner and outer electrodes or between one electrode and ground Often this occurs either because the tube isn t properly seated or because of damaged tubes or dirty and or wet conditions that have allowed carbon tracking to temporarily connect two electrodes...

Page 14: ...n and pure quality air that is typically found at higher mountain elevations AtmosAir s unique and proven air purification process significantly reduces mold controls the spread of bacteria and airborne viruses and reduces airborne particles that evade normal filtration solutions AtmosAir equipment uses non thermal plasma technologies to generate bi polar Ionization that attacks and breaks down od...

Page 15: ...TIONS OF CLEAN AIR GROUP HERIN ARE EXPRESSLY GRANTED IN LIEU OF ALL WARRANTS WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO THE TERM OF THE EXPRESS WARRANTY GRANTED HEREIN Some states do not allow limita...

Reviews: