EC DECLARATION OF CONFORMITY
Clayton Associates, Inc. of 1650 Oak Street, Lakewood New Jersey 08701 U.S.A. declare on our own responsibility that the
following equipment:
Industrial HEPA Filtered, Electrically Powered Vacuum Cleaners
• Vacuum Models (where XXXX is the Tank Model):
WGX‑XXXX‑0, WGP‑XXXX‑0, WTX‑XXXX‑0, WTP‑XXXX‑0
WGX‑XXXX‑1, WGP‑XXXX‑1, WTX‑XXXX‑1, WTP‑XXXX‑1
• Tank Models:
115G,115T,205G, 205T, 215G, 215T
• With serial numbers ranging from
WH0000001
through
WH9999999
Were tested to verify the integrity of the HEPA filter and the assembled machine.
Test Procedure:
• The test was performed using an aerosol generator and a photometer.
•
The system was challenged with 18 microliters/mᶟ Poly Alfa Olefin (PAO).
•
The system was fitted with a HEPA filter, part number 627‑12H having a certified minimum efficiency of 99.995%.
Test Results:
•
The filtration efficiency of the assembled WartHog vacuum was 99.9978%
• Test performed at: 740 Driving Park Avenue, Rochester NY 14613 USA
Declaration:
•
The assembled unit meets the standard for US HEPA filtration and EU H14.