SAFE FILTER CHANGE
Repair or Warranty Contact
Clayton Associates, Inc.
•
1650 Oak Street
•
Lakewood, New Jersey 08701
•
P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com
•
Page 9
When used to collect hazardous material, personal protective equipment should be used when opening the vacuum
The bag filter should be replaced when ¾ full
1. Attach the Grounding Cable
•
This is required only if the vacuum will be used in the
presence of combustible dust
• The grounding cable included should be plugged into the
grounding jack and clamped to either the work piece or the
same grounding point as the work piece
2. Attach the Compressed Air Line
Clayton EXP compressed airlines are conductive and provide compressed air to power the vacuum and as a drain for static buildup
This equipment is only validated for dust ignition proof operation when used with this airline
• Ensure that the compressed air valve on the vacuum is in the off position
• Connect the compressed airline to a compressed air source
• Connect the compressed airline to the compressed air plug on the vacuum
3. Activate the Vacuum
• Rotate the compressed air valve on the vacuum
90 degrees counter-clockwise to start compressed
air flowing and activate the vacuum
4. Pull the Inlet Cap partially off the vacuum
• Rotate the inlet latch 1/4 turn counter clockwise
• Open the inlet and hold it open to relieve the suction
• Grasp the inlet cap and pull while tilting the bottom down until the top of the
cap is disengaged from the vacuum housing
• Be sure that the bag filter remains in the vacuum until the cap is completely removed
• Continue to wiggle the cap off the vacuum and out of the bag
• Use your finger to hold the bag in the vacuum if needed
5. Remove the Bag Filter with a Disposal Bag
• Turn a Disposal Bag inside out over your right hand
• With your bagged hand, grasp the opening in the Bag Filter
• Pull the Bag Filter out of the vacuum while using your left hand to wrap the
Disposal Bag around the Bag Filter
• Keep the open end of the Disposal Bag as close to the vacuum
intake as possible
• Once the Bag Filter is completely inside the Disposal Bag,
Seal the Disposal Bag
• Dispose of the Bag Filter according to your company policy
Grounding Cable
Grounding Jack
Compressed Air Line
Compressed
Air Valve Off
Compressed Air Plug
Compressed
Air Valve On
Inlet Cap
Bag Filter