Installation Examples
Installation #1
With this installation, a back draft damper (optional)
is inserted into the heat run before the plenum of
the existing furnace to prevent air from the existing
furnace to blow back into the furnace when it is not
in use. When a back damper is employed, it should
be located as close to the existing furnace plenum as
practical.
INSTALLATION #2
The baffle on this system should be made the full width
of the furnace plenum in order to properly direct the air
into the distribution ducts.
INSTALLATION #3
Extending the hot air duct from the furnace into the
existing plenum will help direct the flow of air from the
furnace as well as the flow in the existing furnace. Ducting
entering the existing plenum at an angle (approximately
45 degrees) will facilitate air flow from the furnace while
diverting air from the existing furnace.