background image

1.  SAFETY INSTRUCTIONS

Carefully read these instructions before starting the pump.

For safety reasons, persons who have not read the instructions shall not be authorised to 
use the pump. A drainage pump is an electrical appliance and needs due care and 
responsibility when operating. The power cable should never be used to transport or shift 
the pump. Always use the handle of the pump for these operations.

The pump cannot be used to pump salty water, sewage, inflammable, corrosive or 
explosive liquids (i.e. petrol, fuel, diluents), grease, oils or food stuff.

In case power cable is damaged, to avoid any risk, replacement must be done by the 
manufacturer of the pump or by an authorised service centre.

Never remove the plug by pulling on the power cord.

Before handling the pump always remove the plug from the power socket.

Before starting the pump, verify that:

•   The electric system is equipped with a Residual Current Device (RCD) with a rated 

residual operating correct of no greater than 30 mA.

•   The voltage and frequency shown (240V/50Hz) on the technical nameplate of the pump 

correspond to the data of the electric supply system.

•   The power cable of the pump is not damaged

•   The electric connection is done in a dry area at a safe distance from possible flooding.

•   Pump is suited for application: grey water / clean water , pressure requirements etc.

6.  MAINTENANCE AND CLEANING

7.  WARRANTY POLICY

Before doing any maintenance on the pump, always remove the plug from the power 
supply.

Wear protective cloths when doing any maintenance work, gloves, protective eye wear 
etc.

Periodically, it is advisable to make sure that no dirt, leaves sand etc. has accumulated in 
the collection pit.

It is absolutely necessary to protect pump from freezing. If the temperature falls below 
the freezing point, remove the pump from the liquid and store it in a safe place where it 
cannot freeze.

Clayton Engineering warrant this product for 2 years from the date of purchase. The 
warranty covers manufacturer’s defects in material or workmanship. The warranty does 
not cover malfunctions due to misuse or due to failure to follow the instructions in the 
instruction manual. Any alterations to the product are to be performed by a Clayton 
Engineering approved service agent. Any repairs performed by non approved personnel 
may void the warranty.

To make a claim, contact Clayton Engineering, 26 French Ave, Brendale, Q, 4500 on 
phone 1300 798 022 or email [email protected]. You will be asked to 
provide proof of purchase and then will be instructed on the procedure for repairing or 
replacement of the product under warranty. All costs incurred for repair or replace, and 
additional claims can be discussed at this stage.

This warranty is provided in addition to other rights and remedies you have under law: 
Our goods come with guarantees that cannot be excluded under the Australian 
Consumer Law. You are entitled to a replacement or refund for a major failure and for 
compensation for any other reasonably foreseeable loss or damage. You are also entitled 
to have the goods repaired or replaced if the goods fail to be of acceptable quality and 
the failure does not amount to a major failure.

1st January 2012.

Summary of Contents for PROSUB 6

Page 1: ...OSUB 6 9 FILTERED GREY WATER CLEAN WATER BLUESUB 15 BLUEDIVER BLUESUB 6 CL_SUB OM_03 2012 INSTALLATION OPERATION TROUBLE SHOOTING For any assistance or after sales service call Claytech on our toll free number 1300 798 022 Please have a look at further quality Claytech products at www claytech com au BRISBANE 26 French Avenue Brendale Qld 4500 T 1300 798 022 F 07 3881 2780 MELBOURNE 24 Healey Rd D...

Page 2: ...s when doing any maintenance work gloves protective eye wear etc Periodically it is advisable to make sure that no dirt leaves sand etc has accumulated in the collection pit It is absolutely necessary to protect pump from freezing If the temperature falls below the freezing point remove the pump from the liquid and store it in a safe place where it cannot freeze Clayton Engineering warrant this pr...

Page 3: ... application where a high head is required These pumps can handle water temperature up to 35 C Submersible pumps with float are not suitable for continuous operation Problem Possible Cause Solutions Pump delivers little or no water a suction screen on some models could be clogged a Clean suction screen b Air bubble in the pump body b submerged pump should be tilted and gently shaken with discharge...

Page 4: ...st be stopped by either the float switch or turning off the power switch The pump must never be allowed to run dry Never leave the pump in operation when the delivery pipe is clogged The pump must be placed in a stable position inside a collection pit or in the lowest part of the place where it is to be installed All pumps except the ProSub6 9 have an adjustable float switch which starts and stops...

Reviews: