background image

6

HY B-EYE K25 TEATRO

28

28

Reversal of the display 

- Fig. 9

To activate this function, press UP

B

and DOWN

C

keys simultaneously while the display is in the rest mode. This status will be memorised and

maintained even for the next time it will be switched on.  To return to the initial state, repeat the operation all over again.

Setting the projector starting address

On each projector, the starting address must be set for the control signal (addresses from 1 to 512). 

The address can also be set with the projector switched off.

Setting the projector Fixture ID 

On each projector, the Fixture ID address must be set for an easy identification of the fixtures in an installation (ID from 1 to 255).

The Fixture ID address can be set with the projector switched off.

9

Functions of the buttons - Using the menu

Setting addresses and options with the projector disconnected

The projector’s DMX address, as well as other possible operating options, can also be set when the appliance is disconnected from the electricity supply.
All that is needed is to press

F

to momentarily activate the display and thus access the settings. Once the required operations have been carried out,

the display will switch off again after a wait time of 30 seconds.

USING THE MENU: 

1) Press 

F

once – “Main Menu” appears on the display.

2) Use the UP 

B

and DOWN 

C

keys to select the menu to be used:

• Setup (Setup Menu): To set the setting options.
• Option (Option Menu): To set the operating options
• Informations (Informations Menu): To read the counters, software version and other  information.
• Manual Control (Manual control Menu): To trigger the test and manual control functions.
• Test (Test Menu): To check the proper functionning of  effects
• Advanced (Advanced Menu): Access to the "Advanced menu" is recommended for a trained technical personnel.

3) Press 

F

to display the first item in the selected menu.

4) Use the UP 

B

and DOWN 

C

keys to select the MENU items.

Confirms  the  displayed  value,  or  activates  the  displayed  function,  or  enters  the  successive
menu.

Decreases the value displayed (with auto-repetitions) or passes to the next item in the menu.

Increases the value displayed (with auto-repetitions) or passes to the previous item in a menu.

Return to the top level.

Commute from units, tens, hundreds, in the "Address", "Fixture ID" and "Calibration" menù. 

F
C

DOWN

B

UP

D

LEFT

E

RIGHT

Summary of Contents for CL3015

Page 1: ... meet your expectations and requirements INDEX Page Contents 2 1 Safety information 3 2 Unpacking and preparation 4 3 Installation and start up 4 3 1 Installing the fixture 4 3 2 Connecting to manis supply 5 3 3 Connecting the control signal line DMX Art Net 5 3 4 Switching on the fixture and basic SetUp 7 4 Maintenance 7 4 1 Maintenance and Caution 8 4 2 Battery removal 9 4 3 Opening the covers 1...

Page 2: ...olgendem Link auffindbar www claypaky com Ref FIS01I Safety Information HY B EYE series INFORMACIONES DE SEGURIDAD IMPORTANTE Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto Además está disponible una versión digital de la misma en el siguiente enlace www claypaky com Ref FIS01I Safety Information HY B EYE series CONSIGNES DE SÉCURITÉ IMPORTA...

Page 3: ...ATRO 4 5 4 5 45 4 5 45 90 9 0 9 0 9 0 UNLOCKED LOCKED PAN Mechanism Lock and Release every 90 Fig 2 TILT Mechanism Lock and Release every 45 Fig 3 2 3 Packing contents Fig 1 2 x 183102 805 1 2 UNPACKING AND PREPARATION ...

Page 4: ...truss or on the ceiling or wall WARNING with the exception of when the projector is positioned on the floor the safety cable must be fitted Cod 105041 003 available on request This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base 3 INSTALLATION AND START UP 3 1 Installing the fixture 3 2 Connecting to manis supply ...

Page 5: ...ed than when this condition occurs any possible value that has been modified but not yet confirmed with the Fkey will be cancelled 1 2 Dmx Address Warning Message Fixture ID 8 Connecting to the control signal line DMX Fig 7 Use a cable conforming to specifications EIA RS 485 2 pole twisted shielded 120Ohm characteristic impedance 22 24 AWG low capacity Do not use microphone cable or other cable wi...

Page 6: ...ily activate the display and thus access the settings Once the required operations have been carried out the display will switch off again after a wait time of 30 seconds USING THE MENU 1 Press F once Main Menu appears on the display 2 Use the UP B and DOWN C keys to select the menu to be used Setup Setup Menu To set the setting options Option Option Menu To set the operating options Informations ...

Page 7: ...t depends on various factors such as the amount of the effects and the quality of the working environment air humidity presence of dust salinity etc It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations General cleaning of internal parts Restoring lubrication of all parts subject to friction us...

Page 8: ...RO 1 3 5 4 6 2 Battery removal Fig 11 This product contains a rechargeable battery To preserve the environment please dispose the battery at the end of its life according to the regulation in force 11 4 2 Battery removal ...

Page 9: ...9 HY B EYE K25 TEATRO 1 3 4 2 12 Opening the covers Fig 12 4 3 Opening the covers ...

Page 10: ...st the entry of solid bodies larger than 12mm 0 47 No protection against the entry of liquids NOISE LEVEL Min 35 0 dBA background 32 5 ELECTRONICS Long life auto charging buffer battery Preset color and graphic effect macros Function reset controllable from a central control unit Menu driven internal self test function Ethernet ready with RJ45 socket Display backlit black and white graphic LCD dis...

Page 11: ...xhausted or defective Signal transmission cable faulty or disconnected Incorrect addressing Fault in the electronic circuits Lenses broken Dust or grease deposited Check the power supply voltage Call an authorised technician Replace the cables Check addresses see instructions Call an authorised technician Call an authorised technician Clean see instructions 6 CAUSE AND SOLUTION OF PROBLEMS ...

Page 12: ...CLAYPAKY S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 www claypaky com IST022 001 EN Rev 0 06 2020 ...

Reviews: