background image

6

PANIFY

Connecting to the mains supply 

- Fig. 5

 

 

Mains

5

Connecting to the control signal line (DMX)

- Fig. 6

Use a cable conforming to specifications EIA RS-485: 2-pole twisted, shielded, 120Ohm characteristic impedance, 22-24 AWG, low capacity. Do not use

microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 5 pin male/female

connectors. A terminating plug must be inserted into the last fixture with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3.

IMPORTANT:

The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the

shield braid and to pin 1 of the connectors.

SIGNAL

SCREEN

DMX 512

5 PIN

1

2

3

4

5

SIGNAL

6

3.3 Connecting the control signal line: DMX / Art-Net

Summary of Contents for CA3006

Page 1: ...d best meet your expectations and requirements ENGLISH CA3006 PANIFY INDEX Page Contents 2 1 Safety information 3 2 Unpacking and preparation 4 3 Installation and start up 4 3 1 Installing the fixture 5 3 2 Connecting to manis supply 6 3 3 Connecting the control signal line DMX Art Net 8 3 4 Switching on the fixture and basic SetUp 10 4 Maintenance 10 4 1 Opening the covers 11 4 2 Battery removal ...

Page 2: ...r folgendem Link auffindbar www claypaky com Ref FIS026 Safety information Panify INFORMACIONES DE SEGURIDAD IMPORTANTE Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto Además está disponible una versión digital de la misma en el siguiente enlace www claypaky com Ref FIS026 Safety information Panify CONSIGNES DE SÉCURITÉ IMPORTANT Claypaky rec...

Page 3: ...3 PANIFY DMX cable POWER cable 1 Packing contents Fig 1 2 x 183102 805 2 UNPACKING AND PREPARATION ...

Page 4: ... on a truss or on the ceiling or wall WARNING with the exception of when the fixture is positioned on the floor the safety cable must be fitted Cod 105041 001 FUN00C 001 available on request Safety cables must be fitted on the fixing point on the base of the Panify and also between Panify and the fixture installed on it 3 1 Installing the fixture ...

Page 5: ... Power IN Ethernet DMX THRU 5 pin DMX IN 5 pin Display User buttons Power OUT DMX THRU 5 pin Power OUT 3 Control panel Fig 3 2 1 1 3 2 4 Connecting and disconnecting power cable Fig 4 3 2 Connecting to manis supply ...

Page 6: ...from those specified The end connections must be made using XLR type 5 pin male female connectors A terminating plug must be inserted into the last fixture with a resistance of 120Ohm minimum 1 4 W between terminals 2 and 3 IMPORTANT The wires must not make contact with each other or with the metal casing of the connectors The casing itself must be connected to the shield braid and to pin 1 of the...

Page 7: ...You have to connect the fixture associated to the Panify Panify MAINS OUT You have to connect the fixture associated to the Panify Panify DMX THRU You should connect other Panify Panify MAINS OUT You should connect other Panify Panify MAINS IN Panify DMX IN 7 ...

Page 8: ...ed the display automatically returns to rest status It should be noted than when this condition occurs any possible value that has been modified but not yet confirmed with the Fkey will be cancelled 1 Dmx Address 8 3 4 Switching on the fixture and basic SetUp 28 28 Reversal of the display Fig 9 To activate this function press UP B and DOWN C keys simultaneously while the display is in the rest mod...

Page 9: ...on Option Menu To set the operating options Informations Informations Menu To read the counters software version and other information Manual Control Manual control Menu To trigger the test and manual control functions Test Test Menu To check the proper functionning of effects Advanced Advanced Menu Access to the Advanced menu is recommended for a trained technical personnel 3 Press Fto display th...

Page 10: ...cally clean the parts subject to dust and grease deposits The frequency with which the following operations are to be carried out depends on various factors such as the amount of the effects and the quality of the working environment air humidity presence of dust salinity etc It is recommended that the fixture undergoes an annual service by a qualified technician for special maintenance involving ...

Page 11: ...This product contains a rechargeable battery To preserve the environment please dispose the battery at the end of its life according to the regulation in force 10 4 2 Battery removal 11 PANIFY ...

Page 12: ...pply Signal transmission cable faulty or disconnected Incorrect addressing Fault in the electronic circuits Check the power supply voltage Replace the cables Check addresses see instructions Call an authorised technician 6 CAUSE AND SOLUTION OF PROBLEMS CLAYPAKY S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 www claypaky com IST02I 001 EN Rev 0 06 2022 ...

Reviews: