Switching on the fixture - Fig. 9

Press the switch. The fixture starts resetting the effects. At the same time, the following information scrolls on the display:

                                         Model                                      Firmware                             xxx (Fixture ID)                      System errors

                                                         REFLECTXION                       Version X.X.X                      Dmx Address xxx                 E: .........................

                                                                                                         Date - Hour                                                                        W: .........................

On conclusion of resetting in case of absence of the dmx signal, Pan and Tilt move to the “Home” position (Pan 128 bit - Tilt 128 bit). The control
panel (Fig. 8) has a display and buttons for the complete programming and management of the fixture menu. The display can be in one of two
conditions: rest status and setting status. When it is in the rest status, the display shows the fixture’s DMX address. 

During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status.
It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the

F

key will be cancelled.

Dmx Address

Warning Message

Fixture ID

 

 

9

Connecting to the control signal line (DMX) - Fig. 8
Use  a  cable  conforming  to  specifications  EIA  RS-485:  2-pole  twisted,  shielded,  120Ohm  characteristic  impedance,  22-24  AWG,  low  capacity.  Do  not  use
microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 5-pin male/female
connectors. A terminating plug must be inserted into the last fixture with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3.
IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the
shield braid and to pin 1 of the connectors.

Connecting to the mains supply - Fig. 7
Connecting fixture to fixture - Fig. 7a

Mains

 

   

 

 

 

 

 

SIGNAL

SCREEN

DMX 512

5 PIN

1

2

3

4

5

SIGNAL

7

In/Out True1

Max 15 fixtures

Max 1600 VA

Mains

7a

8

Continue  

3.3 Connecting the control signal line: DMX / Art-Net

3.4 Switching on the fixture and basic SetUp

Summary of Contents for CA3000

Page 1: ...DMX Art Net 5 3 4 Switching on the fixture and basic SetUp 7 4 Maintenance 7 4 1 Periodical cleaning 8 4 2 Battery removal 9 5 Specifications 10 6 Cause and solution of problems Congratulations on choosing a Claypaky product We thank you for your custom Please note that this product as all the others in the rich Claypaky range has been designed and made with total quality to ensure excellent perfo...

Page 2: ...endem Link auffindbar www claypaky com Ref FIS01W Safety informatio ReflectXion INFORMACIONES DE SEGURIDAD IMPORTANTE Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto Además está disponible una versión digital de la misma en el siguiente enlace www claypaky com Ref FIS01W Safety informatio ReflectXion CONSIGNES DE SÉCURITÉ IMPORTANT Claypaky r...

Page 3: ...90 9 0 9 0 9 0 UNLOCKED LOCKED PAN Mechanism Lock and Release every 90 Fig 2 TILT Mechanism Lock and Release every 45 Fig 3 2 3 Packing contents Fig 1 4 5 4 5 45 4 5 45 4 5 4 5 2 UNPACKING AND PREPARATION 2x 183102 805 ...

Page 4: ...n the fixture is positioned on the floor the safety cable must be fitted Cod 105041 003 available on request This must be securely fixed to the support structure of the fixture and then connected to the fixing point at the centre of the base Main Switch PowerCon True 1 IN DMX 5 pin IN Ethernet PowerCON True 1 OUT DMX 5 pin THRU Display Functional buttons 2 1 1 2 3 5 6 3 INSTALLATION AND START UP 3...

Page 5: ...value that has been modified but not yet confirmed with the Fkey will be cancelled Dmx Address Warning Message Fixture ID 9 Connecting to the control signal line DMX Fig 8 Use a cable conforming to specifications EIA RS 485 2 pole twisted shielded 120Ohm characteristic impedance 22 24 AWG low capacity Do not use microphone cable or other cable with characteristics differing from those specified Th...

Page 6: ...ly activate the display and thus access the settings Once the required operations have been carried out the display will switch off again after a wait time of 30 seconds USING THE MENU 1 Press F once Main Menu appears on the display 2 Use the UP B and DOWN C keys to select the menu to be used Setup Setup Menu To set the setting options Option Option Menu To set the operating options Informations I...

Page 7: ...ence of dust salinity etc Use a soft cloth dampened with any detergent liquid for cleaning the mirrors It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations General cleaning of internal parts Restoring lubrication of all parts subject to friction using lubricants specifically supplied by Claypa...

Page 8: ...ry To preserve the environment please dispose the battery at the end of its life according to the regulation in force 5 4 1 2 6 3 4 2 Battery removal 8 REFLECTXION 12 Battery not replaceable The following information are intended to remove the battery before disposal ...

Page 9: ...ssion diagnostics Firmware upgrade with no power CPU only Firmware upload from another fixture CPU only Firmware Upgrade via Web Server Protocols Functions RDM Web Server ArtNet Extremely reliable communication RS485 bus BODY Aluminum and steel structure with plastic covers Two side handles for transportation Device locking PAN and TILT mechanisms for transportation and maintenance Optional safety...

Page 10: ...S No mains supply Signal transmission cable faulty or disconnected Incorrect addressing Fault in the electronic circuits Mirror broken Dust or grease deposited Check the power supply voltage Replace the cables Check addresses see instructions Call an authorised technician Call an authorised technician Clean see instructions 6 CAUSE AND SOLUTION OF PROBLEMS ...

Page 11: ...11 REFLECTXION ...

Page 12: ...CLAYPAKY S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 Fax 39 035 301876 www claypaky it IST01U 001 EN Rev 0 01 2020 ...

Reviews: