background image

REFLECTXION

6

28

28

Reversal of the display - Fig. 10

To activate this function, press UP 

B

and DOWN 

C

keys simultaneously while the display is in the rest mode. This status will be memorised and

maintained even for the next time it will be switched on.  To return to the initial state, repeat the operation all over again.

Setting the projector starting address

On each projector, the starting address must be set for the control signal (addresses from 1 to 512). 

The address can also be set with the projector switched off.

Setting the projector Fixture ID 

On each projector, the Fixture ID address must be set for an easy identification of the fixtures in an installation (ID from 1 to 255).

The Fixture ID address can be set with the projector switched off.

10

Functions of the buttons - Using the menu

Setting addresses and options with the fixture disconnected
The projector’s DMX address, as well as other possible operating options, can also be set when the appliance is disconnected from the electricity supply.
All that is needed is to press

F

to momentarily activate the display and thus access the settings. Once the required operations have been carried out,

the display will switch off again after a wait time of 30 seconds.

USING THE MENU: 

1) Press 

F

once – “Main Menu” appears on the display.

2) Use the UP 

B

and DOWN 

C

keys to select the menu to be used:

• Setup (Setup Menu): To set the setting options.
• Option (Option Menu): To set the operating options
• Informations (Informations Menu): To read the counters, software version and other  information.
• Manual Control (Manual control Menu): To trigger the test and manual control functions.
• Test (Test Menu): To check the proper functionning of  effects
• Advanced (Advanced Menu): Access to the "Advanced menu" is recommended for a trained technical personnel.

3) Press

F

to display the first item in the selected menu.

4) Use the UP 

B

and DOWN 

C

keys to select the MENU items.

Confirms  the  displayed  value,  or  activates  the  displayed  function,  or  enters  the  successive
menu. 

Decreases the value displayed (with auto-repetitions) or passes to the next item in the menu.

Increases the value displayed (with auto-repetitions) or passes to the previous item in a menu.

Return to the top level

Commute from units, tens, hundreds, in the "Address", "Fixture ID" and "Calibration" menù. 

F
C

DOWN

B

UP

D

LEFT

E

RIGHT

Summary of Contents for CA3000

Page 1: ...DMX Art Net 5 3 4 Switching on the fixture and basic SetUp 7 4 Maintenance 7 4 1 Periodical cleaning 8 4 2 Battery removal 9 5 Specifications 10 6 Cause and solution of problems Congratulations on choosing a Claypaky product We thank you for your custom Please note that this product as all the others in the rich Claypaky range has been designed and made with total quality to ensure excellent perfo...

Page 2: ...endem Link auffindbar www claypaky com Ref FIS01W Safety informatio ReflectXion INFORMACIONES DE SEGURIDAD IMPORTANTE Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto Además está disponible una versión digital de la misma en el siguiente enlace www claypaky com Ref FIS01W Safety informatio ReflectXion CONSIGNES DE SÉCURITÉ IMPORTANT Claypaky r...

Page 3: ...90 9 0 9 0 9 0 UNLOCKED LOCKED PAN Mechanism Lock and Release every 90 Fig 2 TILT Mechanism Lock and Release every 45 Fig 3 2 3 Packing contents Fig 1 4 5 4 5 45 4 5 45 4 5 4 5 2 UNPACKING AND PREPARATION 2x 183102 805 ...

Page 4: ...n the fixture is positioned on the floor the safety cable must be fitted Cod 105041 003 available on request This must be securely fixed to the support structure of the fixture and then connected to the fixing point at the centre of the base Main Switch PowerCon True 1 IN DMX 5 pin IN Ethernet PowerCON True 1 OUT DMX 5 pin THRU Display Functional buttons 2 1 1 2 3 5 6 3 INSTALLATION AND START UP 3...

Page 5: ...value that has been modified but not yet confirmed with the Fkey will be cancelled Dmx Address Warning Message Fixture ID 9 Connecting to the control signal line DMX Fig 8 Use a cable conforming to specifications EIA RS 485 2 pole twisted shielded 120Ohm characteristic impedance 22 24 AWG low capacity Do not use microphone cable or other cable with characteristics differing from those specified Th...

Page 6: ...ly activate the display and thus access the settings Once the required operations have been carried out the display will switch off again after a wait time of 30 seconds USING THE MENU 1 Press F once Main Menu appears on the display 2 Use the UP B and DOWN C keys to select the menu to be used Setup Setup Menu To set the setting options Option Option Menu To set the operating options Informations I...

Page 7: ...ence of dust salinity etc Use a soft cloth dampened with any detergent liquid for cleaning the mirrors It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations General cleaning of internal parts Restoring lubrication of all parts subject to friction using lubricants specifically supplied by Claypa...

Page 8: ...ry To preserve the environment please dispose the battery at the end of its life according to the regulation in force 5 4 1 2 6 3 4 2 Battery removal 8 REFLECTXION 12 Battery not replaceable The following information are intended to remove the battery before disposal ...

Page 9: ...ssion diagnostics Firmware upgrade with no power CPU only Firmware upload from another fixture CPU only Firmware Upgrade via Web Server Protocols Functions RDM Web Server ArtNet Extremely reliable communication RS485 bus BODY Aluminum and steel structure with plastic covers Two side handles for transportation Device locking PAN and TILT mechanisms for transportation and maintenance Optional safety...

Page 10: ...S No mains supply Signal transmission cable faulty or disconnected Incorrect addressing Fault in the electronic circuits Mirror broken Dust or grease deposited Check the power supply voltage Replace the cables Check addresses see instructions Call an authorised technician Call an authorised technician Clean see instructions 6 CAUSE AND SOLUTION OF PROBLEMS ...

Page 11: ...11 REFLECTXION ...

Page 12: ...CLAYPAKY S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 Fax 39 035 301876 www claypaky it IST01U 001 EN Rev 0 01 2020 ...