CLAY&BAILEY MODEL 1700 Operation & Maintenance Manual Download Page 2

 

Mild operating conditions 

– Vented vapors of internal fluids and outside air that does not         

cause a residue to form, or excessive corrosion on working parts of the manway and/or 
vapor or gas moving through the manway is constant and no surge shock is 
encountered. 

 

Extreme operating condition 

– Internal vapors, particulate or liquid under operating 

conditions that will cause product buildup or corrosion of manway. Pressure or vacuum 
surges and shock occurring on areolar basis during operation. 

 

 

 

 

Operating Conditions 

 

Number of Inspections/Month 

 

 

 

Normal 

 

 

 

 

 

 

 

Extreme 

 

 

 

 

2 -4* 

 

 

*Depending on the rate of buildup or severity of the conditions. 

 

GENERAL INSPECTION PROCEDURE 

CAUTION: Pressure or vacuum conditions in the tank must be relieved and 
must be in a non-operating state before releasing cams, removing hood or 
entering the tank through manhole. 

DOME 

1.  Inspect the rain hood dome (16) for holes and damage where moisture may 

enter. Replace immediately the dome if damage. 
 

2.  Check the dome for excessive dents and distortion that may restrict the flow into 

and out of the pressure/vacuum manway. 
 

3.  Clean out any product buildup and/or debris around the dome and between the 

dome and the manway. 
 

4.  Remove the dome from the support rods (17) by removing the nuts (18) on top of 

the dome and inspect the rods for straightness and corrosion. Replace any that 

Reviews: