22
ALPHA SPOT HPE 700
405
(15.94")
385
(15.16")
390
(15.35")
220
(8.66")
615
(24.21")
505
(19.88")
415
(16.34")
470
(18.50")
Power supplies available
100-120V 50/60Hz
200-240V 50/60Hz
Input power
• 1050VA a 230V 50Hz.
Lamp:
Discharge lamp.
• Type MSR Gold 700/2 Mini Fast Fit (L10098)
- Cap PGJX28
- Colour temperature 7200 K
- Luminous flux 50000 lm
- Average life 750 h
- Any working position
• Type MSR Gold 700/1 Mini Fast Fit (LAM003)
- Cap PGJX28
- Colour temperature 5600 K
- Luminous flux 54000 lm
- Average life 750 h
- Any working position
Motors
20 stepper motors, operating with microsteps,
totally microprocessor controlled.
Optical unit
Elliptic reflector with high luminous efficiency
Channels
Max 29 control channels.
Inputs
• DMX 512
Movable body
• Movement by means of two stepper motors, con-
trolled by microprocessor.
• Automatic repositioning of PAN and TILT after
accidental movement not controlled by control
unit.
• Travel:
- PAN = 540°
- TILT = 250°
• Maximum speeds:
- PAN = 3.77 (normal) / 3.20 (fast)
- TILT = 2.19 (normal) / 1.89 (fast)
• Resolution:
- PAN = 2.11°
- PAN FINE = 0.008°
- TILT = 0.98°
- TILT FINE = 0.004°
IP20 protection rating
• Protected against the entry of solid bodies larger
than 12mm (0.47”).
• No protection against the entry of liquids.
CE Marking
Complies with the following European Directives
- 2006/95/EC (LVD)
- 2004/108/EC (EMC)
- 2011/65/EU (RoHS).
Safety Devices
• Bipolar circuit breaker with thermal protection.
• Automatic break in power supply in case of
overheating or failed operation of cooling system.
Cooling
Forced ventilation with axial fans.
Body
• Aluminium structure with die-cast plastic cover.
• Two side handles for transportation.
• Device locking PAN and TILT mechanisms for
transportation and maintenance.
Working position
Functioning in any position.
Weight
about 22.90 Kg (50lbs 6ozs).
TECHNICAL INFORMATION
CAUSE AND SOLUTION OF PROBLEMS
THE PROJECTOR WILL NOT SWITCH ON
PROBLEMS
ELECTRONICS NON-OPERATIONAL
DEFECTIVE PROJECTION
REDUCED LUMINOSITY
POSSIBLE CAUSES
CHECKS AND REMEDIES
No mains supply.
Lamp exhausted or defective.
Signal transmission cable faulty or disconnected.
Incorrect addressing.
Fault in the electronic circuits.
Lenses or reflector broken
Dust or grease deposited.
Check the power supply voltage.
Replace the lamp. (See instructions).
Replace the cables.
Check addresses (see instructions).
Call an authorised technician.
Call an authorised technician.
Clean (see instructions).