Clavia DMI
Service manual Nord C1 Combo Organ rev. 1.0
Page 5
Available tests are:
[ prog ] Main board
1
.
bd
Mainboard
Performs test 4,5,7
2
.
Fn
Final
Only used in production
3
.
Ht
Heat
Only used in production
4
.
ds
DSP
Tests the two DSP´s, including external memory.
5
.
EP
EEPROM
Performs a quick test of the EEPROM.
6
.
EP
.
EEPROM Long
Tests the entire EEPROM.
7
.
FL
Flash
Performs a quick test of the Flash circuits.
Flash data is not altered.
8
.
FL
.
Flash Long
Tests the entire Flash memory area.
Flash data is not altered.
9
.
ni
MIDI
Tests MIDI communication. Connect a MIDI cable from MIDI in
to MIDI out and then to Bass Pedal MIDI.
Successful test is presented as
O__O
A
.
yb
Keyboard
Press one key at a time. Test counts number of keys pressed.
Upper and lower switch is indicated by the dots in the display
b
.
Pd
Pedal
Tests the function of the pedal inputs.
To fully test the Rotor control a half moon switch must be used.
Sustain
Rotor
Swell
P
pressed
F
fast
C
connected
r
released
S
slow
C
.
LE
Leslie
Only used in production
d
.
AU
Audio
Only used in production
[ Live 1 ] Panel board
1
.
Pn
Panelboard
Performs test 2-3
2
.
bt
Button
Tests the function of all the buttons
3
.
Ad
ADC
Tests the function of the A/D converter on the panel board.
Knobs incl. swell pedal
[ Live 2 ] System
1
.
Sn
Serial no.
Read the serial no. by pressing [on] - [soft] - [fast] - [third]
buttons in the percussion section of the panel board.
2
.
CS
Checksum
Only used in production
3
.
EF
Erase Flash
Will set all data in Flash to “1”
4
.
CL
Clear EEPROM
Will set all data in EEPROM to “0”