3. Technical Specifications
3.1 General Data
HE8360
HE8370
HE8380
Maximum height
M
3.0
4.0
Door width
M
2.0
1.5
2.0
Heat medium
Electric heated
Heat setting
kW
9 / 18
9 / 18
12 / 24
Fan type / dia
Crossflow / 150mm
Fan settings
3
Switching type
AC-ACR-PANEL
Weight
kg
60.0
49.0
60.0
Electrical Data
Supply voltage
415V 3ph 50Hz
Total load
kW
18.4
24.4
A/pha
25.6
34.0
Motor power
W
370
Max Starting current*
amps
5.0
Max Running current*
amps
2.1
External fuse size amps
A/pha
32
32
40
Programmer keypad
pt. no.
AC-ACR-PANEL
Program keypad control wiring
Screened twisted pair 28AWG
Cable terminal size
6.0mm² Max
Mains terminal block position
Separate din rail E; N; L1; L2 & L3
Control terminal block position
Right side of base unit ter12V, DATA & GND
Air Data
Air volume
Low speed
m³/h
2900
1600
2900
Medium speed
m³/h
4100
2400
4100
High speed
m³/h
5000
3300
5000
Air velocity
Low @ 0M
m/s
6.0
Medium @ 0M
m/s
8.5
High @ 0M
m/s
11.0
High @ 1M
m/s
5.2
5.5
5.2
High @ 2M
m/s
3.6
3.7
3.6
High @ 3M
m/s
2.4
2.5
2.4
High @ 4M
m/s
1.4
1.6
1.4
Delta T
Low speed
°C
27
35
36
Medium speed
°C
19
27
26
High speed
°C
15
22
20
Noise level @ 3M
in free field
Low speed
dBA
50
Medium speed
dBA
55
High speed
dBA
60
Dims Data
Length
mm
2138
1638
2138
Depth (width)
mm
350
Height including outlet
mm
395 ( Chassis - min 502 max 563)
Outlet length
mm
2095
1595
2095
Outlet depth
mm
65
Outlet height
mm
Flush ( Chassis - min 107 max 168)
Drop rod mounting rear to ctr on depth
mm
119
Drop rod side to 1st Centre
mm
38
Drop rod mounting centres on length
mm
2062
1562
2062
Wall mounting side to 1st centre
mm
73
Wall mounting top to 1st centre
mm
75
Wall mounting centres on length
mm
1992
1492
1992
Wall mounting centres on height
mm
240