41001380 Iss 01 

 

ALWAYS  ENSURE  THAT  THE  MAIN  EXTER-
NAL  ELECTRICITY  SUPPLY  IS  SWITCHED 

OFF  BEFORE  COMMENCING  ANY  MAINTE-
NANCE ON THIS HEATER. 

 

To  obtain  the  best  results  from  the  heater,  it  is  es-
sential  to  avoid  the  accumulation  of  dust  and  dirt 
within  the  unit  on the  air inlet  and  discharge  grilles. 
For  this  reason  regular  cleaning  is  necessary,  pay-
ing particular attention to the removal of dirt build up 
on the rotor blades.  
 
Cleaning  of  the  fan  is  best  carried  out  with  a  soft 
brush. 
 
The product should be serviced annually.          
 
Servicing  shall  be  undertaken  by  a  competent   per-
son.  
 

6.2  General 

 

If the air curtain does not operate after switching on, 
then  a  suitably  competent  service  engineer  should 
be called to identify the nature of the fault. 
 
All Air Curtains are fitted thermal cut-outs and motor 
thermal protection. 
 
Other  faults  in  relation  to  the  element,  motor  and 
wiring  should  be  identified  using  conventional  fault 
finding techniques. 
 
In the event that electrical components are replaced, 
please ensure that electrical safety checks in accor-
dance with the regulations in force in the country of 
use are undertaken. 
 

6.3 Thermal and fault protection 

 
The  units  are  protected  from  overheating  in  the 
event of fan failure or an obstruction of the free air-
flow by thermal cut-outs. 
 
 
 

 

 

6. Servicing & Maintenance 

6.1 Maintenance

 

If  this  happens,  the  thermal  cut-outs  effectively 
switch  off  the  appliance  by  disconnecting  power  to 
the  control  circuit.  The  appliance  will  not  operate 
until  the  thermal  cut-outs  are  manually  reset.  This 
should be done by a competent electrician. 
 
The heaters are also protected by thermal fuses to 
prevent  catastrophic  failure.  The  thermal  fuse  will 
trip  and  disconnect  power  to  the  affected  heater. 
Thermal fuses are not resettable.  

 
6.4  Fault Conditions 
 

If the heater will not operate, disconnect it from the 
mains  and  arrange  for  a  certified  electrician  to  at-
tend to investigate the reason. 

 

6.5  Replacing Fan Heater Assembly 

 
Remove the lid. 
 
Disconnect the internal wiring from the main termi-
nal block. Remove the four nuts and washers fixing 
the  fan  heater  assembly  to  the  back  of  the  case. 
The  fan  heater  assembly  can  now  be  eased  for-
ward  and  removed  from  the  heater  case.  Fit  re-
placement  fan  heater  and  reassemble  in  reverse 
order. 

 

6.6  Spares 
 

It is essential when ordering spares or replacement 
parts  to  state  the  model  number  and  the  serial 
number  on  the  rating  place  fixed  to  the  top  of  the 
unit. 
 
In the interest of progress the Company reserve the 
right to vary specifications from time to time without 
notice.  The material listed is offered subject to the 
Company’s  General  Conditions  of  Sale,  a  copy  of 
which can be obtained on request. 

Consort Equipment Products Ltd 

Registered Office:  Thornton Industrial Estate 
Milford Haven, Pembrokeshire, SA73 2RT 
Tel:  01646 692172  Fax:  01646 695195 
 
BS EN ISO 9001 Registered Company No FM12671 

Summary of Contents for RAC1509

Page 1: ...1646 692172 Fax 01646 695195 Email enquiries consortepl com Web www consortepl com SCREENZONE RECESSED WARM AIR CURTAINS CATALOGUE NUMBERS RAC1509 RAC1512 INSTALLATION AND OPERATING MANUAL INDEX Secti...

Page 2: ...tions in force in the country of use These instructions must be handed to the user on completion of the installation Installers and service engineers must be able to demonstrate competence and be suit...

Page 3: ...41001380 Iss 01 3 2 Dimensions 2 1 Air Curtain Dimensions...

Page 4: ...to each other to cover the full door opening across wider entrances The weight of the RAC13 heaters is 20kg 3 2 Clearance Distance It is recommended that a minimum clearance of 55mm is allowed around...

Page 5: ...r catenary wire can be used to fasten the air curtain to the ceiling support structure The height between the ceiling face and the top of the air curtain case needs to be adjusted to circa 140mm to en...

Page 6: ...y means other than the remote switch supplied eg BMS then the heat output can be selected by connecting the appropriate terminals WIRED TERMINALS RAC1309 RAC1312 2 3 4 or 5 9000W 12000W 2 4 or 5 3000W...

Page 7: ...Connections To switch on the appliance and operate the blower depress the left hand switch marked on off To change the fan speed use fan boost switch When the heat 1 switch only marked with a single...

Page 8: ...his happens the thermal cut outs effectively switch off the appliance by disconnecting power to the control circuit The appliance will not operate until the thermal cut outs are manually reset This sh...

Page 9: ...41001380 Iss 01 9 Fig 18 Wiring diagram RAC1509...

Page 10: ...41001380 Iss 01 10 Fig 19 Wiring diagram RAC1512...

Reviews: