41001380 Iss 01 

 

 

5.1  Controls 

 
 
 
 
 
 
All  RAC15  heaters  are  supplied  with  a  remote 
switch  that  gives  the  following  functions;  On/off, 
fan, fan boost and heat. 
 
For  thermostatic  control,  a  room  thermostat  with 
6A switch rating maybe connected to the circuit.  
 
The  thermostat  should  be  wired  between  the  ter-
minal 1 and the heater remote switch. 

5. Operation. 

4. Electrical Connections. 

To switch on the appliance and operate the blower, 
depress the left-hand switch (marked “on/off”). 
 
To change the fan speed use fan/boost switch. 
 
When the heat 1 switch only (marked with a single 
bar) is depressed the heat output is ⅓ of full heat.  
RAC1509 - 3kW,RAC1512 - 4kW 
 
When the heat 2 switch only (marked with a double 
bar) is depressed the heat output is ⅔ of full heat. 
RAC1509 - 6kW,RAC1512 - 8kW 
 
When both heat switches are depressed the full heat 
output is available. 
RAC1509 - 9kW,RAC1512 - 12kW 

Fig.13  Electrical connections label

 

Fig.14 Earth connection

 

Summary of Contents for RAC1509

Page 1: ...1646 692172 Fax 01646 695195 Email enquiries consortepl com Web www consortepl com SCREENZONE RECESSED WARM AIR CURTAINS CATALOGUE NUMBERS RAC1509 RAC1512 INSTALLATION AND OPERATING MANUAL INDEX Secti...

Page 2: ...tions in force in the country of use These instructions must be handed to the user on completion of the installation Installers and service engineers must be able to demonstrate competence and be suit...

Page 3: ...41001380 Iss 01 3 2 Dimensions 2 1 Air Curtain Dimensions...

Page 4: ...to each other to cover the full door opening across wider entrances The weight of the RAC13 heaters is 20kg 3 2 Clearance Distance It is recommended that a minimum clearance of 55mm is allowed around...

Page 5: ...r catenary wire can be used to fasten the air curtain to the ceiling support structure The height between the ceiling face and the top of the air curtain case needs to be adjusted to circa 140mm to en...

Page 6: ...y means other than the remote switch supplied eg BMS then the heat output can be selected by connecting the appropriate terminals WIRED TERMINALS RAC1309 RAC1312 2 3 4 or 5 9000W 12000W 2 4 or 5 3000W...

Page 7: ...Connections To switch on the appliance and operate the blower depress the left hand switch marked on off To change the fan speed use fan boost switch When the heat 1 switch only marked with a single...

Page 8: ...his happens the thermal cut outs effectively switch off the appliance by disconnecting power to the control circuit The appliance will not operate until the thermal cut outs are manually reset This sh...

Page 9: ...41001380 Iss 01 9 Fig 18 Wiring diagram RAC1509...

Page 10: ...41001380 Iss 01 10 Fig 19 Wiring diagram RAC1512...