5.1 Controls
All RAC15 heaters are supplied with a remote
switch that gives the following functions; On/off,
fan, fan boost and heat.
For thermostatic control, a room thermostat with
6A switch rating maybe connected to the circuit.
The thermostat should be wired between the ter-
minal 1 and the heater remote switch.
5. Operation.
4. Electrical Connections.
To switch on the appliance and operate the blower,
depress the left-hand switch (marked “on/off”).
To change the fan speed use fan/boost switch.
When the heat 1 switch only (marked with a single
bar) is depressed the heat output is ⅓ of full heat.
RAC1509 - 3kW,RAC1512 - 4kW
When the heat 2 switch only (marked with a double
bar) is depressed the heat output is ⅔ of full heat.
RAC1509 - 6kW,RAC1512 - 8kW
When both heat switches are depressed the full heat
output is available.
RAC1509 - 9kW,RAC1512 - 12kW