background image

 

 

C

USTOMER

 H

ELPLINE

 

 

Should you need any advice on the use of your new Consort product please contact our Helpline: 

 

Consort Equipment Products Limited 

Thornton Industrial Estate, Milford Haven, Pembrokeshire, SA73 2RT 

Tel: 01646 692172   Fax: 01646 695195   Email: [email protected]   Web: www.consortepl.com 

Operation hours: Mon to Thu 8.30am to 4.30pm | Fri 8.30am to 3.30pm 

BS EN ISO 9001 Registered Company No FM12671 

41000972 iss 07 

Wiring diagram 

NOTE:  This  unit  is  suitable  for  remote  control  operation, 
with  the  use  of  remote  control  switch  part  no.  HE8407. 
The two independent feeds must be used on 6kW heat-
ers as shown on the diagram.  
This  optional  control  switch  is  useful  if  you  have  the  unit 
mounted  up  high,  as  you  would  need  a  step  ladder  to 
reach the switches.  You can fit the HE8407 lower down, 
allowing you to easily change the heat settings. 

Remote control—HE8407

 

Operation

 

The right hand switch connects the mains supply to the fan 
motor (giving a cool airflow) and energises the heat control 
switches. 

Heat control HE8320

 

When  the  centre  switch  (marked  with  a  single  bar)  is 
pressed  the  heat  output  is  1.5kW.    When  the  left-hand 
switch (marked with two bars) is pressed the heat output is 
3kW.    When  both  switches  are  pressed  the  heat  output  is 
4.5kW. 

Heat control HE7426

 

When  the  centre  switch  (marked  with  a  single  bar)  is 
pressed the heat output is 3kW.  When the left-hand switch 
(marked with a single bar) is pressed the heat output is 3kW.  
When both switches are pressed the heat output is 6kW. 

NOTE: The unit MUST be reliably earthed

To replace a switch

 

1. 

Remove the top cover. 

2. 

Release  the  three  fixings  which  secure  the  switch 
bracket to the right hand side of the main case. 

3. 

Remove the push-on connectors, noting their position. 

4. 

Remove  by  compressing  the  plastic  retaining  tabs, 
and lifting out the switch. 

To replace the fan heater assembly

 

Remove the top cover. 
Disconnect the internal wiring from the main terminal block 

and earth stud. 

Release the three fixings which secure the switch bracket to 

the right hand of the main case. 

Remove the four nuts and washers fixing the fan heater as-

sembly to the back of the case. 

The  fan  heater  assembly  can  now  be  eased  forward  and 

removed from the heater case. 

Fit replacement fan heater and reassemble in reverse order. 

Spares  

It is essential when ordering spares or replacement parts 
to state the model number and the serial number on the 
rating place fixed to the top of the unit. 
 
In the interest of progress the Company reserve the right 
to  vary  specifications  from  time  to  time  without  notice.  
The  material  listed  is  offered  subject  to  the  Company’s 
General Conditions of Sale, a copy of which can be ob-
tained on request. 
 

NOTE:  DO NOT COVER any of the air inlet or outlet grills, 
at any time. 

Reviews: