Mounting 

When  mounted  over  a  standard  shop  doorway 
the unit should be fitted as low as possible and not 
more than 2.3 meters from ground level.  A single 
unit  will  provide  reasonable  coverage  for  a  one 
metre doorway, and for wider doorways units can 
be mounted end to end. 
The unit should be positioned so that the airflow is 
not obstructed by any part of the doorframe. 

Installation  

Carefully unpack the unit and remove the top cov-
er fixing screws.  The heater may be mounted using 
the mounting bracket provided. 
 
Loosen  mounting  screws,  allowing  the  mounting 
bracket to be removed from the unit.  Making sure 
that  the  mounting  bracket  is  horizontal,  fix  the 
bracket to the wall using 4 x No 8 wood screws. 
 
Place  the  unit  on  the  mounting  bracket  ensuring 
the washers are spaced as shown on diagram 2 (a 
plain washer either side of the mounting bracket). 
Tighten screws to hold the unit at the required an-
gle. 

Wall bracket assembly 

The  heater  may  also  be  mounted  directly  onto  a  suitable  wall  or  bearer  by  four  No.  8  wood  screws 
through the holes provided in the back of the unit casing.  Keyhole slots are provided for the top two 
fixings. 

Electrical connections 

These units are suitable for connection to a 230/240 volt 50 Hz single phase ac supply.  The heaters con-
sume 4.5kW & 6kW respectively at 240 volts when switched to the full heat position. 
 
Model HE8320 – 4.5kW 

Model HE7426 – 6kW 
The appliance should be connected to the supply via a circuit in which there is an all-pole switch.  Test 
for correct operation and refit the cover. 

41000972 iss 07 